Workshop Manuals Factory service & repair Volkswagen
01 4-cyl. injection engine with timing chain02 4-cyl engine03 Fault finding; Power transmission04 5-speed manual gearbox 02T05 6-speed automatic gearbox 09G06 09G Gearbox07 02R Gearbox08 02T Gearbox09 Brake systems10 Wheels and Tyres Guide: Standard11 Running gear; axles; steering12 Running gear, axles, steering13 Brakes14 Wheels and Tyres Guide15 Heating; air-conditioning16 Electrical: General Information17 Electrical: Communication18 Electrical19 General body repairs, exterior20 General body repairs, interior21 Body Interior
Volkswagen Polo Vivo, South Africa (2010-2017)15 · Heating; air-conditioning
15 · Heating & A/C

Reservoir

Make
Volkswagen
Model
Polo Vivo, South Africa
Year
2010–2017
Section
General information on refrigerant circuit › Reservoir
Heating; air-conditioningReservoir

Reservoir

The reservoir collects the vaporised and gaseous mixture coming from the evaporator to ensure the air conditioner compressor receives only gaseous refrigerant. Gaseous refrigerant is formed from the vapour.

V87-1403

Refrigerant oil flowing in the circuit does not remain in the reservoir, as an oil extraction hole has been provided.

Moisture which has entered the refrigerant circuit during repairs will be collected by a filter (desiccant bag) in the reservoir.

Gaseous refrigerant with oil is drawn in by the air conditioner compressor.

Note

  • Renew the reservoir if the refrigerant circuit has stood open for any length of time (more than the normal repair time) and moisture has entered the system, or if it is required because of a specific complaint .
  • Do not remove sealing plugs (A) and (B) until just before installation.
  • The desiccant bag in an unsealed reservoir will become saturated with moisture within a short time and is then unusable.
  • When installing, observe arrow indicating direction of flow, if applicable.

Parts & tools for this job For 2010 Volkswagen Polo