O-ring
- Make
- Volkswagen
- Model
- Polo Vivo, South Africa
- Year
- 2010–2017
- Section
- General notes on air conditioning systems › O-ring
‹ Prev Basics for working on refrigerant circuitNext › Before operating the air conditioning system after recharging with refrigerant
Heating; air-conditioningO-ring
O-ring
- Use only O-rings that are resistant to refrigerant R134a and related refrigerant oils. O-rings are no longer colour-coded. Coloured and black O-rings are used.
- Check that the O-rings used have the correct internal diameters.
Rep. gr.87
Parts catalogue
- Never reuse O-rings.
- Before installing, moisten O-rings lightly with refrigerant oil (PAG oil).
Note
- When purging components with compressed air and nitrogen, always collect the gas mixture exiting the component with suitable exhaust gas extraction equipment (workshop fume extractor).
- After completion of repair work screw sealing caps (with seals) onto valve and service connections.
Before operating the air conditioning system. Check the vehicle-specific charge quantities Rep. gr.87.
Do not top up a charged refrigerant circuit; discharge refrigerant present and recharge system.
‹ Prev Basics for working on refrigerant circuitNext › Before operating the air conditioning system after recharging with refrigerant
Parts & tools for this job For 2010 Volkswagen Polo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Polo 2010 cabin filter
As an Amazon Associate we earn from qualifying purchases.