Rabbit L5-2.5L (CBUA) (2008)
Refrigerant Oil: Specifications
Refrigerant Oil
NOTE:
-
The special refrigerant oil (for use with refrigerant circuits R134a only) is no longer obtainable on the refrigerant/machine oil market.
-
Do not use refrigerant oil that was stored for long periods of time in open containers.
Refrigerant oil can be obtained using following part No.; for:
7SEU16C; Denso
G 052 300 A2
7SEU17C; Denso
G 052 300 A2
PXE16; Sanden
G 052 154 A2
DSC17E; Zexel/Valeo
G 052 154 A2
Important information:
Refrigerant oil attracts moisture. Close any opened containers immediately after use to prevent moisture from entering.
Refrigerant oil, because of its chemical properties, must not be disposed of with engine oils or transmission oils.
Oil Distribution
The oil, which is located in the sump of the A/C compressor before initially switching on the air conditioner system, is distributed through the refrigerant
circuit as follows:
-
A/C compressor approximately 50%
-
Condenser approximately 10%
-
Suction hose approximately 10%
-
Evaporator approximately 20%
-
Fluid reservoir approximately 10%