Checking for leaks
- Make
- Volkswagen
- Model
- Scirocco Mk3
- Year
- 2008–2017
- Section
- Brake booster and brake master cylinder › Checking for leaks
Checking for leaks
Note
- The average air pressure of the earth's atmosphere at sea level is 1013 mbar and decreases steeply as the altitude increases (approx. 100 mbar/1,000 m altitude). Local and time fluctuations also influence vacuum generation.
- A cold engine, a switched-on air-conditioning system as well as engine idling have an adverse influence on generation of a vacuum.
Before starting work, check all vacuum hoses for damage (e.g. cracks or marten bite) and to check that they are correctly and firmly attached
Connect brake booster vacuum gauge VAS 6721Chapter.
Open cut-off valve (A).
Close cut-off valves (B+C).

Start warm engine (>60° C), press accelerator briefly (engine speed greater than 2000/min).
Normally (see notes), the vacuum that is generated should be between 600 and 950 mbar (depending on engine size).
Open cut-off valve (C) to evacuate brake booster.

Switch off engine.
Read and make a note of measured value shown.
A vacuum decrease of 400 mbar in 12 hours is permissible.
If the vacuum decrease is greater, check for leaks in the vicinity of...
Brake boosterornon-return valve, vacuum hoses with connectors or vacuum pump/intake pipe.If there are large leaks, the vacuum decreases steeply within a few seconds.
After generation of vacuum, close cut-off valve (A) in order to check brake booster vacuum system.

After generation of a vacuum, close cut-off valve (C) in order to check vacuum system from brake booster vacuum gauge VAS 6721 to intake pipe or to vacuum pump.

Open cut-off valve (B) to facilitate removal of hose connections and adapter.
Parts & tools for this job For 2008 Volkswagen Scirocco
- TOOLBrake bleeder kitSearch: one man brake bleeder kit
- FLUIDBrake fluidSearch: brake fluid
- TOOLBrake line flaring toolSearch: brake line flaring tool
As an Amazon Associate we earn from qualifying purchases.