Checking fuel delivery rate
- Make
- Volkswagen
- Model
- Scirocco Mk3
- Year
- 2008–2017
- Section
- Fuel pump › Checking fuel delivery rate
Checking fuel delivery rate


Note
- When driving characteristic problems occur when the fuel tank is a approx. 1/4 filled, then check fuel delivery rates with approx. 1/4 filled tank or less.
Observe safety precautions → Chapter.
Observe rules for cleanliness → Chapter.
Remove rear bench seat General body repairs, interiorRep. gr.72Rear seat; Removing and installing bench seat / individual seats.
If fuel pump control unit J538(2) is fitted, remove from cover (1).

Unclip cover (1) at retaining tabs (arrows), using removal wedge 3409.

Check that connector (arrow) is fitted securely by pulling connector without pressing catch. The connector can cause a fault if it has not been fitted correctly.

Release and unplug connector (arrow).
Check contacts on plug and on fuel delivery unit for damage.
Connect test instrument adapter/DSO (5-pin) VAS 5565 to connector and fuel delivery unit.

Connect remote control V.A.G 1348/3A to adapter VAS 5565 and to battery positive terminal in engine compartment.
Note
- This step serves only to have the fuel pump running when the engine is stopped.
The delivery rate of the fuel pump depends on the battery voltage. Therefore also connect multimeter V.A.G 1526E to contacts (1) and (5) of adapter VAS 5565.

Pull off supply line (1). Separate plug-in connectors → Chapter.

Warning The fuel line is under pressure.
Risk of injury to eyes and skin from fuel.
Wear eye protection and protective clothing to avoid eye injuries and skin contact. Before loosening hose connections, wrap a cloth around the connection. Then release pressure by carefully opening the connection point.
Collect escaping fuel with a cleaning cloth.
Connect hose VAS 6550/2 to connection (A) of pressure tester VAS 6550.

Connect hose VAS 6550/2 between fuel line leading from fuel tank and pressure tester VAS 6550.
Connect pressure regulating valve VAS 6550/4 to connection (B) of pressure tester VAS 6550
Hold end of hose of pressure regulating valve VAS 6550/4 in measuring container.
Ensure plug-in connectors are secured properly by pulling.
Ensure that drain tap (C) on pressure tester(1) is closed.

Shut-off valves (A) and (B) on pressure tester(1) are open.
Press remote control V.A.G 1348/3A.
Note
- The fuel system pressurisation pump G6 will be actuated.
Set pressure of 4.0 bar on pressure regulating valve(arrow) using adjuster wheel.

Keep the adjuster in this position from this point on.
Drain measuring container.
Press remote control for 60 seconds whilst measuring voltage at fuel pump.
Compare delivered quantity of fuel with specification indicated in chart.

| Name of axis | Unit |
|---|---|
| Minimum delivery rate | cm3 |
| Voltage at fuel pump with engine not running and pump running. | Volt |
Example:
During the test a voltage of 10.5 volts is measured. This equates to a minimum delivery rate of approx. 1,200 cm3 in 60 seconds.

Open tank flap unit.
Clean area around fuel filler neck.
Unscrew cap from fuel filler neck (arrow).
Repeat fuel delivery rate check Anchor.
Check fuel tank breather → Chapter.
Check fuel lines for possible restrictions (kinks) or blockages.
Check fuel lines for leaks and damage.
Check fuel delivery rate at fuel filter as follows:

Pull fuel supply line (arrow) off fuel filter. Separate plug-in connectors → Chapter.
Warning The fuel line is under pressure.
Risk of injury to eyes and skin from fuel.
Wear eye protection and protective clothing to avoid eye injuries and skin contact. Before loosening hose connections, wrap a cloth around the connection. Then release pressure by carefully opening the connection point.
Connect pressure tester VAS 6550 to fuel supply line (2) by means of hose VAS 6550/1.

Connect hose VAS 6550/1 to connection (A) of pressure tester VAS 6550.
Connect pressure regulating valve VAS 6550/4 to connection (B) of pressure tester VAS 6550
Hold end of hose of pressure regulating valve VAS 6550/4 in measuring container.
Ensure that drain tap (C) on pressure tester(1) is closed.

Shut-off valves (A) and (B) on pressure tester(1) are open.
Press remote control V.A.G 1348/3A.
Note
- The fuel system pressurisation pump G6 will be actuated.
Set pressure of 4.0 bar on pressure regulating valve(arrow) using adjuster wheel.

Keep the adjuster in this position from this point on.
Drain measuring container.
Press remote control for 60 seconds whilst measuring voltage at fuel pump.
Check fuel line leading to engine for possible restrictions (kinks) or blockages.
Check fuel line leading to engine for leaks and damage.
If no fault is detected:
Renew fuel filter → Chapter.
Proceed as follows to check fuel delivery rate at fuel delivery unit:

Pull fuel lines (1) off flange. Separate plug-in connectors → Chapter.
Warning The fuel line is under pressure.
Risk of injury to eyes and skin from fuel.
Wear eye protection and protective clothing to avoid eye injuries and skin contact. Before loosening hose connections, wrap a cloth around the connection. Then release pressure by carefully opening the connection point.
Connect pressure tester VAS 6550 to fuel delivery unit (1) using hose VAS 6550/2.

Connect hose VAS 6550/2 to connection (A) of pressure tester VAS 6550.
Connect pressure regulating valve VAS 6550/4 to connection (B) of pressure tester VAS 6550
Hold end of hose of pressure regulating valve VAS 6550/4 in measuring container.
Ensure that drain tap (C) on pressure tester(1) is closed.

Shut-off valves (A) and (B) on pressure tester(1) are open.
Press remote control V.A.G 1348/3A.
Note
- The fuel system pressurisation pump G6 will be actuated.
Set pressure of 4.0 bar on pressure regulating valve(arrow) using adjuster wheel.

Keep the adjuster in this position from this point on.
Drain measuring container.
Press remote control for 60 seconds whilst measuring voltage at fuel pump.

Remove fuel delivery unit → Chapter.
Check fuel lines for possible restrictions (kinks) or blockages.
Remove fuel delivery unit and check filter strainer for dirt.
Check fuel lines for leaks and damage.
Check that all fuel delivery unit (1) hose connections (arrows) are connected.
Check current draw of fuel pump → Chapter.
If no fault was detected in the current draw:
Renew fuel delivery unit → Chapter.
If fuel delivery rate has been attained, but nevertheless you suspect a fuel supply system fault (e.g. intermittent failure of fuel supply system):
Check current draw of fuel pump → Chapter.
Parts & tools for this job For 2008 Volkswagen Scirocco
- PARTFuel filterSearch: Volkswagen Scirocco 2008 fuel filter
- TOOLFuel pressure test kitSearch: fuel pressure test kit
- TOOLFuel line disconnect toolSearch: fuel line disconnect tool
As an Amazon Associate we earn from qualifying purchases.