Test procedure
- Make
- Volkswagen
- Model
- Scirocco Mk3
- Year
- 2008–2017
- Section
- Repairing heating system, passenger compartment › Test procedure
Heating, air conditioningTest procedure
Test procedure
Remove left footwell vent → Chapter.
Remove centre console trim from left footwell.
Using vehicle diagnosis, testing and information system VAS 5051B (or successor unit) and 100 A pick-up clamp VAS 5051B/7, measure current draw at earth wire (arrow).

Low heating output: approx. 30 amps
Medium heating output: approx. 60 amps
High heating output: approx. 80 amps
Parts & tools for this job For 2008 Volkswagen Scirocco
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Scirocco 2008 cabin filter