Body self-diagnosisFault table
Fault table
General body repairs, exterior
Note
- Only 4 faults can be displayed. It is therefore necessary to rectify the displayed faults, to perform a functional check → Chapter, and then to read the fault memory again.
- The fault table is listed according to the 5 digit fault code on the left.
- For explanation of fault types (e.g. “open circuit/short circuit to earth”): Operating instructions of fault reader.
- Before renewing components indicated as being faulty, check the wiring and connectors to these components as well as the earth connections using current flow diagram. This is particularly relevant if faults are output as“occurring sporadically” (SP).
- Displayed faults can be localised with the test table.
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 00000 | |
| No fault recognized | If “No fault recognised” appears after carrying out repairs self-diagnosis is ended |
| 00668 | | |
| Vehicle system voltage terminal 30 | | |
| Signal too low | Defective wiring or connectors | Difference to battery voltageRead measured value block; display group number 003 → Chapter, display zone 5; and test table; display group number 003 → Chapter, display zone 5 |
| 01131 | | |
| Turn signal activation | Bulbs defective | Renew bulbs |
Short to earth, open circuit/short to positive | Defective wiring or connectors | Check wiring and connectors using current flow diagramRead measured value block; display group number 003 → Chapter, display zone 4; and test table; display group number 003 → Chapter, display zone 4 |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01132 | | |
| Front infrared sensor G166 | Infrared sensor defective | Renew infrared sensor |
| Defective wiring or connectors | Check wiring and connectors using current flow diagram |
| 01133 | | |
| Rear infrared sensor G167 | Infrared sensor defective | Renew infrared sensor |
| Defective wiring or connectors | Check wiring and connectors using current flow diagram |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01134 | | |
| Alarm horn H12 | Alarm horn H12 defective | Renew alarm horn |
Short to earth, open circuit/short to positive | Defective wiring or connectors | Check wiring and connectors using current flow diagramRead measured value block; display group number 003 → Chapter, display zone 3; and test table; display group number 003 → Chapter, display zone 3 |
| 01135 | | |
| Interior monitoring sensors | Sensors G170 and G171 defective, non functional, under 11 V | Renew sensors |
| Defective wiring or connectors | Check wiring and connectors using current flow diagram |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01137 | | |
| Switch for CL; lock contacts | Switches F59, and F114, and F218 defective | Renew switch |
Short to positive, short to earth | Defective wiring or connectors | Check wiring and connectors using current flow diagramRead measured value block; display group number 01 → Chapter, display zone 1; and test table; display group number 001 → Chapter, display zone 1 |
| 01138 | | |
| Switch for CL; unlocking driver door | Switch F59 defective | Renew switch |
Short to positive, short to earth | Defective wiring or connectors | Check wiring and connectors using current flow diagramRead measured value block; display group number 001 → Chapter, display zone 2; and test table; display group number 001 → Chapter, display zone 2 |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01139 | | |
| Switch for CL; front pass.door unlocking | Switch F114 defective | Renew switch |
| Short to positive | Defective wiring or connectors | Check wiring and connectors using current flow diagramRead measured value block; display group number 001 → Chapter, display zone 3; and test table; display group number 001 → Chapter, display zone 3 |
| 01140 | | |
| Switch for central locking in rear lid F218 | Switch for central locking in rear lid F218 defective | Renew switch |
| Short to positive | Defective wiring or connectors | Check wiring and connectors using current flow diagramRead measured value block; display group number 001 → Chapter, display zone 4; and test table; display group number 001 → Chapter, display zone 4 |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01141 | | |
| Rear lid release switch E165 | Rear lid release switch E165 defective | Renew switch |
| Short to earth | Defective wiring or connectors | Check wiring and connectors using current flow diagram |
| 001142 | | |
| Motors for CL; driver door and tank flap open | Motors in front left central locking actuator F131 and central locking actuator in tank flap F219 defective | Renew actuator General body repairs, exteriorRep. Gr.57Central locking |
| Short to positive | Motors in front left central locking actuator F131 and central locking actuator in tank flap F219 defective | Check wiring and connectors using current flow diagram |
Short to earth open circuit | | Read measured value block; display group number 002 → Chapter, display zone 2; and test table; display group number 002 → Chapter, display zone 2 |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01143 | | |
| Motors for CL; driver door and tank flap open | Motors in front left central locking actuator F131 and central locking actuator in tank flap F219 defective | Renew actuator General body repairs, exteriorRep. Gr.57Central locking |
| Short to positive | | |
| Short to earth | | |
| Open circuit | Defective wiring or connectors | Check wiring and connectors using current flow diagramRead measured value block; display group number 002 → Chapter, display zone 1; and test table; display group number 002 → Chapter, display zone 1 |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01144 | | |
| Motor for CL; front pass. door open | Motors F133 in actuator defective | Renew actuator General body repairs, exteriorRep. Gr.57Central locking |
| Short to positive | | |
| Short to earth | | |
| Open circuit | Defective wiring or connectors | Check wiring and connectors using current flow diagram |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01145 | Motors F132 and F134 in actuator defective | Renew actuator General body repairs, exteriorRep. Gr.57Central locking |
| Motor for CL; rear doors open |
| Short to positive | Defective wiring or connectors | Check wiring and connectors using current flow diagram |
| Short to earth |
| Open circuit |
| 01146 | Motors F133 and F132 and F134 in actuator defective | Renew actuator General body repairs, exteriorRep. Gr.57Central locking |
| Motors for CL; front pass. door and rear doors closed |
| Short to positive | Defective wiring or connectors | Check wiring and connectors using current flow diagram |
| Short to earth |
| Open circuit |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01147 | Motors V120 in actuator defectiveDefective wiring or connectors | Renew actuator General body repairs, exteriorRep. Gr.57Central lockingCheck wiring and connectors using current flow diagram |
| Rear lid lock motor V120 |
| Short to earth |
| 01148 | Defective wiring or connectors | Check wiring and connectors using current flow diagram |
| Activation of safe door locking |
| Short to positive |
| Short to earth |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01149 | | |
| Deactivation of safe door locking | | |
Short to positive, short to earth | Defective wiring or connectors | Check wiring and connectors using current flow diagram |
| 01157 | | |
| Voltage supply for alarm hose | | |
| Signal too low | Defective wiring or connectors | Check wiring and connectors using current flow diagramRead measured value block; display group number 003 → Chapter, display zone 3; and test table; display group number 003 → Chapter, display zone 3 |
| V.A.G 1551 printout | Possible fault cause | Rectifying fault |
|---|
| 01158 | | |
| Voltage supply for turn signals | | |
| Signal too low | Defective wiring or connectors | Check wiring and connectors using current flow diagramRead measured value block; display group number 003 → Chapter, display zone 4; and test table; display group number 003 → Chapter, display zone 4 |
| 01159 | | |
| Wiring for safe locking | Open circuit | Check wiring and connectors using current flow diagram |
| 65535 | | |
| Control unit defective | Electrical interference as a result of external sources, poor earth connections or positive connections to control unit J379 | Test wiring and connections to control unit using current flow diagram |
18 Diagnostics