01 6-cylinder injection engine (4-valve), mechanics02 4-cylinder injection engine (5-valve), mechanics03 4-cylinder diesel engine (1.9 l engine)04 4-cylinder diesel engine (2.0 l engine, 2 valve)05 6-speed manual gearbox 02N, all-wheel drive06 6-speed manual gearbox 02N07 4-speed automatic gearbox 099, four-wheel drive08 Automatic gearbox 099 - 4-speed09 5-speed automatic gearbox 09B10 Wheels and Tyres Guide - Standard11 Running gear, axles, steering - front and four-wheel drive12 Brake systems13 Supplementary heating14 Heating, air conditioning15 Electrical system self-diagnosis16 Electrical system17 Electrical: Communication18 Body self-diagnosis19 General body repairs, interior20 General body repairs, exterior
Volkswagen Sharan Mk1 (1995-2010)14 · Heating, air conditioning
14 · Heating & A/C

Fault table

Make
Volkswagen
Model
Sharan Mk1
Year
1995–2010
Section
Self-diagnosis of Climatronic, vehicles: » 05.00 › Fault table
Heating, air conditioningFault table

Fault table

Note

  • The following table lists all the faults, with the corresponding 5-digit fault codes, that can be detected by the Climatronic control unit J255 and read from the vehicle diagnosis, testing and information system VAS 5051.
  • If faults occur only sporadically or if the fault memory is not cleared after a fault is rectified, these faults will be displayed as “sporadic faults”.
  • The fault table may also include the type of fault.
  • When the repair has been completed, the fault memory must always be read again with the vehicle diagnosis, testing and information system VAS 5051 and cleared.
  • If no faults are detected although there is a complaint about the Climatronic, conduct “Read measured value block”Chapter function. If necessary, perform complaint-related fault finding without self-diagnosis:

Display on VAS 5051Possible cause of faultRectifying fault
0 faults detectedIf “0 faults detected” appears after repairs are completed, the self-diagnosis is ended.
00532
Voltage supply
Signal too largeRemarkAlternator defectiveCheck supply voltage using “Read measured value block”Chapter
Signal too smallRemarkWiring or connectors to Climatronic control unit J255Check wiring and connectors to control unit using circuit diagram Current flow diagrams, Electrical fault finding and Fitting locationsCheck alternator Current flow diagrams, Electrical fault finding and Fitting locations

Note

Display on VAS 5051Possible cause of faultRectifying fault
00605
Two-way valve for fresh air and air recirculation flap N63
Open circuit/short to positiveRemarkShort circuit or open circuit in wiring or connectors to two-way valve for fresh air and air recirculation flap N63Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Short to earthRemarkTwo-way valve for fresh air and air recirculation flap N63 defectiveReplace two-way valve for fresh air and air recirculation flap N63Chapter

Note

Display on VAS 5051Possible cause of faultRectifying fault
00657
Centre vent control motor V102Remark
Short circuit or open circuit in wiring or connectors to centre vent control motor V102Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Check function of control motor → Chapter Functional test of the control motors
Central vent control motor V102 defectiveReplace centre vent control motor V102Chapter

Note

Display on VAS 5051Possible cause of faultRectifying fault
00766
Front vent temperature sender G152
Open circuit/short to positiveRemarkShort circuit or open circuit in wiring or connectors to front vent temperature sender G152Check front vent temperature sender G152 using “Read measured value block”ChapterIf faults are detected in ambient temperature sensor G17, sunlight penetration photosensor G107 or air conditioning system coolant temperature sender G110, first check wiring from control unit to connection -L56- (sender) in wiring harness for Climatronic.
Short to earthRemarkFront vent temperature sender G152 defectiveCheck wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Replace front vent temperature sender G152Chapter

Note

Display on VAS 5051Possible cause of faultRectifying fault
00779
Ambient temperature sensor G17
“- -” will appear in the ambient temperature display if ambient temperature sensor G17 fails.
Open circuit/short to positiveRemarkShort circuit or open circuit in wiring or connectors to ambient temperature sensor G17Check ambient temperature sensor G17 using “Read measured value block”ChapterIf faults are also detected in sunlight penetration photosensor G107, front vent temperature sender G152 or air conditioning system coolant temperature sender G110, first check wiring from control unit to connection L56 (sender) in wiring loom for Climatronic.
Short to earthRemarkAmbient temperature sensor G17 defectiveCheck wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Renew ambient temperature sensor G17Chapter

Note

Display on VAS 5051Possible cause of faultRectifying fault
00792
Air conditioning system pressure switch F129Remark
Short circuit or open circuit in wiring or connectors to air conditioning system pressure switch F129Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Coolant pressure too high or too low due to: incorrect charging of refrigerant circuit or inadequate coolant coolingCheck air conditioning system pressure switch F129 using “Read measured value block 08”Chapter.
Air conditioning system pressure switch F129 defectiveRenew air conditioning system pressure switch F129Chapter

Note ambient temperature sensor G17

malfunctions simultaneously.

Display on VAS 5051Possible cause of faultRectifying fault
00797
Sunlight penetration photosensor G107
Open circuit/short to positiveOpen circuit or short circuit in wiring or connectors to sunlight penetration photosensor G107Check sunlight penetration photosensor G107 using “Read measured value block”ChapterIf faults are detected in ambient temperature sensor G17, front vent temperature sender G152 or air conditioning system coolant temperature sender G110, first check wiring from control unit to connection -L56 (sender) in wiring harness for Climatronic.
Sunlight penetration photosensor G107 defectiveCheck wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Renew sunlight penetration photosensor G107Chapter.
Display on VAS 5051Possible cause of faultRectifying fault
00799
Air conditioning system coolant temperature sender G110
Open circuit/short to positiveRemarkOpen circuit or short circuit in wires or connectors to air conditioning system coolant temperature sender G110Check air conditioning system coolant temperature sender G110 using “Read measured value block”ChapterIf faults are also detected in ambient temperature sensor G17, front vent temperature sender G152 and sunlight penetration photosensor G107, first check wiring from control unit to connection -L56 (sender) in wiring harness for Climatronic.
Short to earthRemarkAir conditioning system coolant temperature sender G110 defectiveCheck wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Renew air conditioning system coolant temperature sender G110Chapter

Note

Display on VAS 5051Possible cause of faultRectifying fault
01086
Speedometer sender G22RemarkShort circuit or open circuit in wiring or connectors from dash panel insert -K- to Climatronic control unit J255Check signal from speedometer sender G22 using “Read measured value block”ChapterCheck wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Speedometer sender G22 on gearbox defective (only if speedometer G21 is also not functioning)Renew speedometer sender G22

A fault in speedometer sender G22

has been detected The fault will be detected only if no speed signal is measured in 5 driving cycles within 2 minutes after the engine is started.

Display on VAS 5051Possible cause of faultRectifying fault
01184
Rear vent temperature sender G174
Open circuit/short to positiveRemarkShort circuit or open circuit in wiring or connectors to rear vent temperature sender G174Check rear vent temperature sender G174 using “Read measured value block”Chapter
Short to earthRemarkRear vent temperature sender G174 defectiveCheck wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Renew rear vent temperature sender G174Chapter.

Note

Display on VAS 5051Possible cause of faultRectifying fault
01185
Rear fresh air blower V80
Short circuit or open circuit in wiring or connectors to rear fresh air blower V80Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Check voltage at rear fresh air blower V80 using “Read measured value block”Chapter
Rear fresh air blower control unit J391 defectiveRenew rear fresh air blower control unit J391.
Rear fresh air blower V80 defectiveRenew rear fresh air blower V80Chapter
Display on VAS 5051Possible cause of faultRectifying fault
01186
Rear air distribution servomotor V136Remark
Short circuit or open circuit in wiring or connectors to rear air distribution control motor V136Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Check function of rear air distribution control motor V136Chapter Functional test of control motors.
Rear air distribution control motor V136 defectiveRenew rear air distribution control motor V136Chapter

Note

Display on VAS 5051Possible cause of faultRectifying fault
01187
Rear temperature flap control motor V137
Short circuit or open circuit in wiring or connectors to rear temperature flap control motor V137Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Check function of rear temperature flap control motor V137Chapter Functional test of control motors.
Rear temperature flap control motor V137 defectiveRenew rear temperature flap control motor V137Chapter
Display on VAS 5051Possible cause of faultRectifying fault
01188
Electrical connection for magnetic clutch control unit
Open circuit/short to positiveRemarkShort circuit or open circuit in wiring or connectors from Climatronic control unit J255 to air conditioning system magnetic clutch N25Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Short to earthRemarkIn vehicles with VR 6 engine: magnetic clutch relay J44 defective In vehicles with all other engines: radiator fan control unit J293 defectiveRenew magnetic clutch relay J44 or radiator fan control unit J293Chapter

Note

Display on VAS 5051Possible cause of faultRectifying fault
01189
Centre flap control motor V70 is displayed in the vehicle diagnosis, testing and information system VAS 5051/ although front air distribution control motor V145 is installed
Short circuit or open circuit in wiring or connectors to front air distribution control motor V145Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Check function of front air distribution control motor V145Chapter Functional test of control motors.
Front air distribution control motor V145 defectiveReplace front air distribution control motor V145Chapter
Display on VAS 5051Possible cause of faultRectifying fault
01271
Temperature flap control motor V68Remark
Short circuit or open circuit in wiring or connectors to temperature flap control motor V68Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Check function of temperature flap control motor V68Chapter Functional test of control motors
Temperature flap control motor V68 defectiveRenew temperature flap control motor V68Chapter

Note

Display on VAS 5051Possible cause of faultRectifying fault
01273
Fresh air blower V2
Short circuit or open circuit in wiring or connectors to fresh air blower V2Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Check voltage at fresh air blower V2 using “Read measured value block”Chapter
Fresh air blower control unit J126 defectiveRenew fresh air blower control unit J126.
Fresh air blower V2 defectiveRenew fresh air blower V2Chapter
Display on VAS 5051Possible cause of faultRectifying fault
65535
Control unit faultyElectrical interference caused by outside sources, poor earth connections or positive connections to Climatronic control unit J255Check wiring and connectors to Climatronic control unit J255 using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations
Dash panel temperature sensor G56 defective. Temperature sensor blower V42 defectiveCheck dash panel temperature sensor G56 using “Read measured value block”Chapter
Climatronic control unit J255 defectiveRenew Climatronic control unit J255 if necessary → Chapter