Workshop Manuals Factory service & repair Volkswagen
01 6-cylinder injection engine (4-valve), mechanics02 4-cylinder injection engine (5-valve), mechanics03 4-cylinder diesel engine (1.9 l engine)04 4-cylinder diesel engine (2.0 l engine, 2 valve)05 6-speed manual gearbox 02N, all-wheel drive06 6-speed manual gearbox 02N07 4-speed automatic gearbox 099, four-wheel drive08 Automatic gearbox 099 - 4-speed09 5-speed automatic gearbox 09B10 Wheels and Tyres Guide - Standard11 Running gear, axles, steering - front and four-wheel drive12 Brake systems13 Supplementary heating14 Heating, air conditioning15 Electrical system self-diagnosis16 Electrical system17 Electrical: Communication18 Body self-diagnosis19 General body repairs, interior20 General body repairs, exterior
Volkswagen Sharan Mk1 (1995-2010)13 · Supplementary heating
13 · Heating & A/C

Fault table

Make
Volkswagen
Model
Sharan Mk1
Year
1995–2010
Section
Auxiliary heater -B4W/ D4W-, vehicles » 05.2000 › Fault table
Supplementary heatingFault table

Fault table

Fault code number and meaningPossible cause of faultFault rectification with remarks
000
No malfunction
001
Overvoltage warning (> 16 V)ControllerRenew
002
Undervoltage warning (< 10.2 V)2nd. batteryCharge
010
Overvoltage shut-off (> 16 V)2nd. batteryVoltage was present for longer than 20 seconds
011
Undervoltage shut-off (< 10.2 V)2nd. batteryVoltages were present for longer than 20 seconds
012
OverheatingTemperature at flame monitor G64 or overheating sensor G189 too high (> 125 °C). Air in coolant circuit, bleed → Chapter
014
Evaluation of temperature difference between flame monitor G64 and overheating sensor G189Air in coolant circuit, flame monitor G64 defective, overheating sensor G189 defectiveBleed → Chapter, check flame monitor G64Chapter, check overheating sensor G189Chapter
015
Continuous shut-downAir in coolant circuit,Bleed → Chapter Clear fault memory → Chapter
017
OverheatingTemperature too high (> 130 °C) at overheating sensor G189 and coolant temperature sender for heater G241Air in coolant circuit, bleed → Chapter Check overheating sensor G189Chapter Check coolant temperature sender for heater G241Chapter Clear fault memory → Chapter
020
Glow plug for heater Q9DefectiveRenew
021
Short circuit on the glow plug for heater Q9Short circuit on the connection or in the glow plugRenew if necessary.
030
Combustion air blower V6BlockedRenew
032
Combustion air blower V6Open circuitCheck the connection, replace if necessary
038
Fresh air blower V2Open circuitCheck,
039Renew if necessary.
Fresh air blower V2Short circuit
041
Circulation pump V55Open circuitCheck, replace if necessary
042and bleed coolant circuit → Chapter
Circulation pump V55Short circuit
047
Metering pump V54Short circuitCheck,
048Renew if necessary.
Metering pump V54Open circuit
050
Continuous shut-downUnsuccessful start attemptsErase fault memory → Chapter.
051
Time overrunWhen blowing flame monitor G64 cold with combustion air blower V6Check flame monitor G64Chapter.
052
Time overrunSafety time exceeded after several start attemptsCheck: exhaust pipe fuel volume, combustion air induction
053
Flame failure from the high control levelMetering pump V54 (quantity delivered) Exhaust pipe (blocked) Combustion air (insufficient) Check,
054Flame monitor G64 (values) Replace if necessary → Chapter
Flame failure from medium control levelThe fault memory is cleared if the start is successful.
056 Heater is permanently switched off.
Flame failure from low control levelClear fault memory after checking and replacing.Switch on heater once again.
060
Coolant temperature sender for heater G241Open circuitCheck water temperature,
061Check coolant temperature sender for heater G241,
Coolant temperature sender for heater G241Short circuitReplace if necessary → Chapter
064
Flame monitor G64Open circuitFlame monitor G64
065Checking → Chapter
Flame monitor G64Short circuit
071
Overheating sensor G189Open circuitCheck,
072
Overheating sensor G189Short circuitReplace if necessary → Chapter
090
Heater control unit J162Error in microprocessor, (memory present)Replace if necessary → Chapter
091
Interference voltageIn vehicle electrical system or other voltage sourcesRectify
092 to 103
Heater control unit J162DefectiveReplacing → Chapter.

Parts & tools for this job For 1995 Volkswagen Sharan

As an Amazon Associate we earn from qualifying purchases.