Calibrating reversing camera R189
- Make
- Volkswagen
- Model
- Tiguan Mk2
- Year
- 2016–2023
- Section
- Reversing camera system › Calibrating reversing camera R189
Calibrating reversing camera R189
Make sure all necessary prerequisites are fulfilled Anchor.
Connect vehicle diagnostic tester.
Fitting the wheel centre mounting VAS 6350/1:
Check the bolt hole circle pattern on the wheels.
Prepare wheel centre mountings VAS 6350/1 accordingly.
To do this, secure 3 wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match pitch circle diameter.
Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.
Fit wheel centre mounting VAS 6350/1 onto wheel securing bolts on front axle.

Wheel centre mountings VAS 6350/1 are positioned and secured in the adapters by the “O-rings”.
Note
- When fitting the wheel centre mountings VAS 6350/1 on the wheels, ensure that any “anti-theft” wheel bolts are not attached to the wheel centre mountings VAS 6350/1.
Adjust paddles using clamping bolts so that they can move freely just above the floor. Make sure the paddles can move freely.
Assembling and setting-up calibration unit VAS 6350Chapter.
Determining the distance:
Switch on spacing laser VAS 6350/2.
The following display appears:
The display shows how the spacing laser VAS 6350/2 must be fitted. Press the respective button.

Hold spacing laser VAS 6350/2(2) flush with bracket on one side of the calibration unit as shown in illustration. Spacing laser VAS 6350/2(2) must make firm contact with bracket.

Briefly press the measurement button.
The laser is switched on.
Laser beam from spacing laser VAS 6350/2(2) must hit lower, larger part of paddle (1).
If this is not the case, position of paddles must be corrected accordingly using clamping bolts on wheel centre mounting VAS 6350/1.
Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350 with one hand while laser beam is visible on paddle.
Press measuring button briefly to measure distance.
Make a note of the displayed value.
Perform same measuring procedure for front wheel on other side of calibration unit VAS 6350.
Measured distance value must be identical on both sides.
If the value is not identical:
Adjust calibration unit VAS 6350 until values on both sides are identical.
When adjusting, make sure that linear laser VAS 6350/3 hits centre of Volkswagen emblem and spirit level display also remains centred. If necessary, readjust accordingly.
Determining dimension (H):

Measure height of calibration unit VAS 6350: dimension (H) (top edge of platform - floor).
Make sure that spacing laser VAS 6350/2 is set correctly (fitted with front edge).
The display shows how the spacing laser VAS 6350/2 must be fitted. Press the respective button.

Note the reading for the height of the calibration unit VAS 6350.
Note
- The vehicle shown in the illustration may differ from the actual vehicle.

Measure (dimension B) between the centre of the reversing camera lens and the wheel support surface using a commercially available folding ruler.
Note the reading for dimension (B).
The measured distance as well as the height of the calibration unit and the centre height of the reversing camera lens must now be entered in “millimetres” into the vehicle diagnostic tester.
Connect vehicle diagnostic tester.
Perform calibration using Vehicle diagnostic tester.
Parts & tools for this job For 2016 Volkswagen Tiguan
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit
As an Amazon Associate we earn from qualifying purchases.