Workshop Manuals Factory service & repair Volkswagen
01 Fuel supply system - Petrol engines02 Fuel supply system - Diesel engines03 4-Cylinder Common Rail Engine (2.0 l, 4V, Turbocharger)04 4-Cyl. Direct Injection Engine (2.0 l, 4 V, EA 888 Gen III BZ, Turbocharger, Chain Drive)05 Propshaft and rear final drive06 7-speed dual clutch gearbox 0DL07 Brake system08 Running gear, axles, steering09 Wheels and Tyres Guide10 Heating, air conditioning11 Heating and air conditioning: Auxiliary heater12 Air conditioning systems with R1234yf refrigerant - General information13 Electrical: Communication14 Electrical system15 General body repairs, exterior16 General body repairs, interior
Volkswagen Tiguan Mk2 (2016-2023)14 · Electrical system
14 · Electrical

Preparatory measures for calibration

Make
Volkswagen
Model
Tiguan Mk2
Year
2016–2023
Section
Lane change assist › Preparatory measures for calibration
Electrical systemPreparatory measures for calibration

Preparatory measures for calibration

Extensive preliminary work is required before the actual calibration can be carried out using the vehicle diagnostic tester.

Prerequisites:

Position vehicle on a firm and level surface.Apply parking brake – the vehicle must not be moved while the calibration procedure is being performed.Turn wheels to straight-ahead position – steering wheel in straight-ahead position.Nobody may be inside vehicle during measurement.Opening and closing the vehicle doors during calibration must be avoided.Special tools and workshop equipment requiredCalibration unit VAS 6350
W00-10488
Vehicle diagnostic tester

Procedure

Connect vehicle diagnostic tester.

Switch on ignition.

Attach 3 wheel bolt adapters (spanner size 17) to each wheel centre mounting VAS 6350/1 for the wheel securing bolts.

N94-10685

Insert measuring paddles in both wheel centre mountings VAS 6350/1, and secure them with clamping nut.

Fit wheel centre mountings VAS 6350/1 onto wheel bolts on both rear wheels.

The turning centre of the wheel centre mounting must be in the turning centre of the wheel.

Note

  • Fit wheel centre mountings VAS 6350/1 onto the wheels so that the “anti-theft wheel bolts” are not connected to the wheel centre mountings.

Adjust measuring paddles with the help of the clamping nuts in such a way that they can move freely just above the floor.

The measuring paddles must not be restricted in movement.The measuring paddles must be vertical.

Position calibration unit VAS 6350 at distance (a) to rear wheels.

A96-10286
Dimension (a ) = 1700 ± 10 mm

Push ON button to switch on spacing laser VAS 6350/2.

N94-10681

Indicated on display of VAS 6350/2:

“- - - m”

Note

  • The laser is switched on at the same time.

Hold spacing laser VAS 6350/2(2) for distance measurement flush with stop bracket as shown in illustration.

N94-10684
When doing this, make sure that spacing laser VAS 6350/2 is firmly in contact with stop bracket.

Ensure that the “laser beam” for distance measurement is at the bottom enlarged part on the measuring paddle (1).

If this is not the case, adjust height of measuring paddles using lock nuts on wheel centre mountings VAS 6350/1.

Now, briefly press ON button to measure distance.

A96-10289

Indicated on display of VAS 6350/2:

“1.700 m” (specification: 1700 ± 10 mm).

Repeat the measuring process from the left stop bracket to the measuring paddle on the rear left wheel.

Measured distance value must be identical on both sides.

If both measured values are not identical, adjust calibration unit VAS 6350 accordingly.

Note

  • The vehicle shown in the illustration may differ from the actual vehicle.
M94-10198

Attach calibration unit for lane change assist VAS 6350/4 on rear left on mounting of calibration unit VAS 6350.

If assembled correctly, the mains power lead should be fitted to the bottom left of the calibration unit (as seen facing direction of normal travel).Dimension (a) = 744 mm (measured from upper edge of calibration unit to workshop floor).

The dimension is set with the measuring point (arrow) at the base of the calibration unit on the scale of the steel rule (1).

Setting dimension left = 769 mm (read off on measuring scale (1)).

Connect the calibration unit for lane change assist VAS 6350/4 to mains voltage.

Bring the calibration unit VAS 6350 to the horizontal position with the aid of the vial (sight glass) (arrow) by turning the plastic feet.

N94-10686

Put on “laser protection glasses”.

Note

  • The vehicle shown in the illustration may differ from the actual vehicle.
N94-13343

Switch on linear laser VAS 6350/3 on calibration unit VAS 6350.

Align the whole calibration unit VAS 6350 so that the laser beam is focused on the rear of the vehicle in the centre above the Volkswagen emblem.

Check the spacing on the left and right again between the stop brackets of the calibration unit VAS 6350 and the measuring paddles (1) on the wheel mountings.

N94-10684
Specification: 1700 ± 10 mm

Calibrating lane change assist control unit → Chapter.

Parts & tools for this job For 2016 Volkswagen Tiguan

As an Amazon Associate we earn from qualifying purchases.