Workshop Manuals Factory service & repair Volkswagen
01 Fuel supply system - Petrol engines02 Fuel supply system - Diesel engines03 4-Cylinder Common Rail Engine (2.0 l, 4V, Turbocharger)04 4-Cyl. Direct Injection Engine (2.0 l, 4 V, EA 888 Gen III BZ, Turbocharger, Chain Drive)05 Propshaft and rear final drive06 7-speed dual clutch gearbox 0DL07 Brake system08 Running gear, axles, steering09 Wheels and Tyres Guide10 Heating, air conditioning11 Heating and air conditioning: Auxiliary heater12 Air conditioning systems with R1234yf refrigerant - General information13 Electrical: Communication14 Electrical system15 General body repairs, exterior16 General body repairs, interior
Volkswagen Tiguan Mk2 (2016-2023)10 · Heating, air conditioning
10 · Heating & A/C

System overview - refrigerant circuit

Make
Volkswagen
Model
Tiguan Mk2
Year
2016–2023
Section
Refrigerant circuit › System overview - refrigerant circuit
Heating, air conditioningSystem overview - refrigerant circuit

System overview - refrigerant circuit

N87-11505
  • Condenser
    Different versions. Refer to Electronic Parts Catalogue.
    Assembly overview → Chapter
    Removing and installing → Chapter
  • Refrigerant line
    To condenser.
  • Refrigerant line, high-pressure side
    Leads to refrigerant line with internal heat exchanger.
  • Service connection, high-pressure side
    Removing and installing → Chapter.
    Protective cap: 0.4 ± 0.1 Nm
    Valve: 2 ± 0.2 Nm
  • Refrigerant line, low-pressure side
    Leads to refrigerant line with internal heat exchanger.
    Depending on the vehicle model, type of refrigerant lines and production period, an additional damper weight may be installed on the refrigerant line Electronic Parts Catalogue.
    Removing and installing damper weight (if fitted) → Chapter
  • Pressure sender for refrigerant circuit G805
    Removing and installing → Chapter.
    5 ± 1 Nm
  • Service connection, low-pressure side
    Removing and installing → Chapter.
    Protective cap: 0.4 ± 0.1 Nm
    Valve: 2 ± 0.2 Nm
  • Refrigerant line with internal heat exchanger
    In the internal heat exchanger, the hot liquid refrigerant flowing on the high-pressure end supplies energy to the cold refrigerant vapour flowing on the low-pressure end, thus enhancing the efficiency of the air conditioner
    From condenser and air conditioner compressor
    Removing and installing → Chapter.
  • Expansion valve
    Removing and installing → Chapter
  • Bolts
    10 Nm
  • Bolt
    8 Nm
  • Nut
    8 Nm
  • Air conditioner compressor
    Assembly overview → Chapter
    Removing and installing → Chapter
    Removing from and installing on bracket → Chapter

Parts & tools for this job For 2016 Volkswagen Tiguan

As an Amazon Associate we earn from qualifying purchases.