Workshop Manuals Factory service & repair Volkswagen
01 6-cylinder injection engine02 8-cylinder injection engine03 6-cylinder diesel engine (3.0 l engine, common rail)04 12-cylinder injection engine05 6-cylinder injection engine (direct injection)06 8-cylinder injection engine (direct injection)07 10-cylinder diesel engine Volkswagen R GmbH08 5-cylinder diesel engine09 10-cylinder diesel engine10 Automatic gearbox 09D Volkswagen R GmbH11 Automatic gearbox 09D12 6-speed manual gearbox 08D13 Transfer box and final drive14 Wheels and Tyres Guide - Standard15 Running gear, axles, steering16 Brake systems17 Supplementary heating18 Heating, air conditioning19 Electrical system20 Electrical: Communication21 General body repairs, interior22 General body repairs, exterior
Volkswagen Touareg Mk1 (2002-2010)19 · Electrical system
19 · Electrical

Charging battery with battery deactivation relay

Make
Volkswagen
Model
Touareg Mk1
Year
2002–2010
Section
Charging battery › Charging battery with battery deactivation relay
Electrical systemCharging battery with battery deactivation relay

Charging battery with battery deactivation relay

The description only applies to predelivery vehicles on which the battery cut-off relay is still installed.

Warning Danger of injury! Note the warnings and safety regulations in Electrical System, General Information!

Warning To prevent damage to the battery or the vehicle, observe the information concerning the different types of battery in Electrical System, General Information.

Warning Batteries where the magic eye is yellow must not be checked or charged. Do not slave/jump start the vehicle!
Danger of explosion when checking and charging or slave/jump starting
These batteries must be renewed.

Note

  • The battery cut-off relay is designed to protect the battery against discharge from electrical consumers on stand-by, for example.
  • As the battery is subject to self-discharge in quiescent condition, it is necessary to regularly check and re-charge the battery according to the specifications of the programme for stationary and stock vehicles when the quiescent current has reached < 12.5 V.
  • When the battery cut-off relay is installed, re-charging the battery via the slave starting points in the engine compartment is not possible as the battery cut-off relay interrupts the charging process after approx. 10 min.
  • Note the special specifications for charging the battery in vehicles fitted with a battery cut-off relay under all circumstances.

Connect the battery charger cable:

Warning

  • Park the vehicle where it is protected from weather conditions.
  • The vehicle may otherwise be damaged due to water ingress.
  • Make sure that the open driver door cannot be damaged.
  • Observe the notes under charging the battery in the workshop manual “Electrical system; General information”.

Switch off ignition and all electrical consumers and remove ignition key.

Open positive terminal cover cap (1) at jump starting point.

N27-10643

Connect positive clamp (A) of battery charger to positive terminal of slave starting point in engine compartment.

N27-10644

Connect negative clamp (B) of battery charger to battery earth strap (1) with driver door open.

N27-10645

Switch on battery charger.

Disconnect the battery charger cable:

Warning

  • Danger of explosion!
  • Switch charging appliance off before disconnecting to avoid spark formation.
  • Sparks generated by electrostatic charging must also be avoided.

Switch off battery charger.

Disconnect battery charger.

Close positive terminal cover at jump starting point.

Parts & tools for this job For 2002 Volkswagen Touareg

As an Amazon Associate we earn from qualifying purchases.