Adapting “shut-off priority of electrical consumer”
- Make
- Volkswagen
- Model
- Touareg Mk1
- Year
- 2002–2010
- Section
- Control units › Adapting “shut-off priority of electrical consumer”
‹ Prev Adapting “actuation time for headlight washer system”Next › Data bus diagnostic interface J533
Electrical systemAdapting “shut-off priority of electrical consumer”
Adapting “shut-off priority of electrical consumer”
This function permits readout and reset after reaching the maximum shut-off priority count.
Each time a load is shut-off, a counter is incremented in the onboard supply control unit J519. The maximum value is 14.
Engine speed increase (voltage less than 12.7 V) - with further reduction and dropping below 12.2 VPTC heater element to 75%Reduction of heat output to 50%PTC heater element to 50%Seat heating and ventilation offWindscreen deactivationPTC heater element to 25%Wiper system heating offMirror heating offPTC heater element offSteering wheel heating offHeated rear window offEngine speed increase 2nd stageAir conditioning system offConnect vehicle diagnosis testerChapter.
On vehicle diagnosis tester, select “guided fault finding” mode.
Using “GoTo” button, select “Functions/component” and the following menu options in succession:
- Body
- Electrical system
- 01 - On Board Diagnostic capable systems
- Onboard supply control unit
- Onboard supply control unit functions
- Adapting shut-off priority
‹ Prev Adapting “actuation time for headlight washer system”Next › Data bus diagnostic interface J533
Parts & tools for this job For 2002 Volkswagen Touareg
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit
As an Amazon Associate we earn from qualifying purchases.