Removing and installing circulation pump V55
- Make
- Volkswagen
- Model
- Touareg Mk1
- Year
- 2002–2010
- Section
- Auxiliary heater components › Removing and installing circulation pump V55
‹ Prev Removing and installing air intake silencerNext › Removing and installing heater cooler shut-off valve N279
Supplementary heatingRemoving and installing circulation pump V55
Removing and installing circulation pump V55
Note
- The coolant circuit must be bled after it is opened Rep. Gr.19.
- Cooling system is pressurized when engine is warm. If necessary, release pressure before carrying out repairs.

Clamp off the coolant hoses.

Loosen clamps (1).
Warning Danger of scalding injuries.
The cooling system is pressurised. When the engine is warm, the coolant temperature may be above 100 0C.
Reduce pressure and temperature before carrying out repairs.
Pull coolant hoses off circulation pump V55.
Loosen screw-type clamp (2).
Unplug electrical connector (3) from circulation pump V55 and remove it.
Install in reverse order.