Preparatory measures for calibration
Extensive preliminary work is required before actual calibration can be carried out using vehicle diagnostic tester.
Park vehicle on hard, level standing.Actuate parking brake - vehicle should not be moved during calibration.On vehicles with air suspension (self-levelling system), set suspension height to “Auto” with engine running. Then set running gear to jacking-up mode MaintenanceBookletDescriptions of work (self-levelling switched off).Nobody may be inside vehicle during calibration.Opening and closing the vehicle doors during calibration must be avoided.Setting unladen weight of vehicle Remark.Note
Special tools and workshop equipment requiredVehicle diagnostic testerCalibration unit VAS 6350
Connecting vehicle diagnostic testerChapter
Check which bolt hole circle the wheels have.
Equip wheel mountings for the Touareg: to do this, secure 3 adapters for the Touareg's wheel bolts to each wheel mounting on hole circle with designation “120” or “130”.
Position paddles on both wheel centre mountings VAS 6350/1 and secure these with the clamp bolt.
Place the wheel centre mountings VAS 6350/1 on the wheel securing bolts of the rear wheels. Wheel centre mountings are positioned and secured in the adapters through »O-rings«.

Note
- Set the wheel centre mountings against wheels so that no »anti-theft wheel bolts« are connected to the wheel mountings.
Use clamping bolts to adjust paddles so that they move freely just above the floor.
Make sure the paddles can move freely.
Position calibration device VAS 6350/4 behind vehicle at a distance of 1.20 m - 1.70 m to the angle brackets of the calibration device and the paddles on the wheel centre mountings of the rear wheels, as shown in the overview diagram (dimension A)Item.
Position the calibration device VAS 6350/4 horizontally. Do this by turning the plastic feet under the calibration unit until the air bubble in the spirit level is precisely in the centre of the indicator (arrow).

Note
- Make sure that the base plate of the calibration unit VAS 6350/4 is evenly illuminated.
- Light reflections on the base plate can interfere with calibration process.
- Check the illumination of the base plate using the camera image on the radio/navigation system screen.
Switch on laser on calibration unit (1) and align the entire calibration unit so that the laser beam hits the rear end of the vehicle centrally above the VW logo.

Switch on the spacing laser VAS 6350/2 for distance measurement by pressing the ON button. The following display appears and the laser is activated:

Hold spacing laser for distance measurement (2) as shown in illustration flush against bracket on one side of calibration unit so that spacing laser lies firmly against bracket.

Ensure that laser beam from spacing laser for distance measurement hits lower, enlarged part of paddle (1).
If this is not the case, adjust paddles accordingly on wheel mounting using clamping bolts.
Hold spacing laser for distance measurement in bracket on calibration device while laser beam is visible on paddle. Now briefly press the ON button to measure distance. The following appears in the display:

The distance is shown on the display in “metres”.
Note the measured value.
Repeat measuring process in same manner for other rear wheel on other side of calibration unit.
Measured distance value must be identical on both sides. If value is not identical, adjust calibration unit until values on both sides are identical.
When adjusting calibration device, ensure that laser beam of line laser continues to hit the vehicle centrally above the VW logo and that the spirit level indicator remains in the centre. Adjust accordingly if required.

Measure height of calibration device, dimension (H) (upper edge of board - floor).
The distance measured, the height of the calibration device and the height of the centre of the reversing camera lens must be entered in vehicle diagnosis, measuring and information system in “millimetres” during calibration.
Calibrating reversing camera → Chapter