Installing sensor strip
- Make
- Volkswagen
- Model
- Touareg Mk2
- Year
- 2010–2018
- Section
- Rear lid › Installing sensor strip
General body repairs, exteriorInstalling sensor strip
Installing sensor strip
Note
- Adhesive remover D 002 000 10 must be used exclusively.
- Ensure that the adhesive surfaces are free of dust and grease.
- Remove protective backing immediately before installation. Working temperature approx. 21 ℃.

Align sensor strip (1) and insert between rear lid (4) and rear window (7).
Pull line (2) into rear lid through rubber grommet (3).
Connect connector (5).
Pull protective film off adhesive tape (6) and press on forcefully.