After each engine start, the flame monitor G64 must inform the auxiliary heater control unit J364 within 130 seconds after the heating has switched on that the flame is burning normally. Otherwise, the auxiliary heater will automatically attempt a second start. If, after the second start, the flame still does not burn normally, the heater will remain switched off until the auxiliary heater is switched on again.
The combustion air blower V6 runs at reduced speed during partial load operation. The metering pump V54 then delivers only approx. 50% of the fuel quantity (lower cycle frequency).
The start procedure is aborted if:
- The flame monitor G64 registers that the flame is not burning normally within 130 seconds.
- Temperature sensor 2 for supplementary and auxiliary heating G587 or temperature sensor G18 detects a temperature of over 125 °C.
- A temperature difference of more than 15 °C exists between temperature sensor 2 for supplementary and auxiliary heating G587 and temperature sensor G18.
- The auxiliary heater control unit J364 has detected a fault. Read out fault memory using vehicle diagnosis tester.