Touareg 2 V6-3.6L (BHK) (2008)
‹› The lower retaining plate must be removed first before the upper retaining plate can be removed.
-
Initiate control motor Basic Setting function with Diagnostic Operation System (VAS 5051B).
-
When SF appears on the left of the Climatronic operating display, switch ignition off.
‹› Control motors can only be re-installed in the service position after removal.
-
Remove the lower retaining plate on the right side of the A/C unit. Refer to --> [ Right Lower A/C Unit Retaining Plate ] See: Housing Assembly
HVAC/Service and Repair/Right Lower A/C Unit Retaining Plate
-
Remove the upper retaining plate screws - 3 -.
‹› To remove the retaining plate the bolts - 1 - are not loosened or removed, they are used for guiding the retaining plate.
‹› Mark the connections for each motor to prevent confusing them.
-
Disconnect connectors.
-
Pull retaining plate and control motors out downwards.
-
If the Right Center Vent Motor (V111) must be replaced, then remove the screws - 4 - (quantity: 3) from the left motor, identified by - A - in the
illustration.
-
If the Right Side Vent Motor (V300) must be replaced, then remove the screws - 4 - (quantity: 3) from the right motor, identified by - B - in the
illustration.
Installing