Removing and installing expansion valve
The expansion valve atomises incoming refrigerant. It regulates the flow so that, depending on the heat transport, the vapour does not become a gas until it reaches the outlet of the evaporator.
Special tools and workshop equipment requiredTorque wrench V.A.G 1331/

Note
- To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
Extract refrigerant using air conditioner service station before opening refrigerant circuit. Comply with notes → Chapter.
Depending on engine, connecting pipe from charge air cooler EnginesRep. gr.21Turbocharging, G-charger and / or upper plenum chamber bulkhead must be removed General body repairs, exteriorRep. gr.50Front body.
Place drip tray for workshop hoist VAS 6208 beneath engine.
CAUTIONWhen the engine is warm, the cooling system is under pressure. Danger of scalding due to steam and hot coolant. There is a risk of injury to the skin and parts of the body due to scalding.Wear protective gloves.Always wear safety goggles.Proceed as follows to release the pressure: cover the cap of the coolant expansion tank with a cloth, and open it carefully.Clamp off coolant hoses (1) with hose clamps up to 40 mm 3093 and disconnect coolant hoses to heat exchanger.

Unscrew nut (1) (6 Nm).

Release clips (2) and remove heat shield (3).
Extract refrigerant with air conditioning service station.
CAUTIONRisk of freezing injury caused by escaping pressurised refrigerant.There is a risk of injury to the skin and parts of the body due to freezing.Wear protective gloves.Always wear safety goggles.Extract refrigerant, and open the refrigerant circuit immediately afterwards.If more than 10 minutes passed since the refrigerant has been extracted, do not open the refrigerant circuit prior to extracting refrigerant anew. Due to re-evaporation, pressure will be built up in the refrigerant circuit.Unscrew bolts (1) (10 ± 1 Nm) and pull out refrigerant lines (2) from expansion valve.
Unscrew bolts (8) (5 ± 0.5 Nm) and remove expansion valve.

- Bolts
10 ± 1 Nm
Qty. 2 - Refrigerant lines on expansion valve
- Sealing ring
13.7 mm; 2.5 mm - Expansion valve
- Sealing ring
14 mm; 1.82 mm
Moisten with refrigerant oil when installing. - Sealing ring
10.8 mm; 1.82 mm
Moisten with refrigerant oil when installing. - Sealing ring
9.5 mm; 2.5 mm - Socket head combi-bolt
5 ± 0.5 Nm
Install in reverse order.
Parts & tools for this job For 2003 Volkswagen Touran
- PARTEngine gasket setSearch: Volkswagen Touran 2003 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set