Note
- The average air pressure of the earth's atmosphere at sea level is 1013 mbar and decreases steeply as the elevation increases (approx. 100 mbar/1,000 m elevation). Local and time fluctuations also influence vacuum generation.
- A cold engine, a switched-on air-conditioning system as well as engine idling have an adverse influence on generation of a vacuum.
Before starting work, check all vacuum hoses for damage (e.g. cracks or marten bite) and to check that they are correctly and firmly attached
Connect brake servo vacuum gauge VAS 6721Chapter.
Open cut-off valve (A).
Close cut-off valves (B+C).

Start warm engine (>60°C), press accelerator briefly (engine speed above 2,000 rpm).
Normally (see notes), the vacuum that is generated should be between 600 and 950 mbar (depending on engine size).
Open cut-off valve (C) to evacuate brake servo.

Switch off engine.
Read and make a note of measured value shown.
A vacuum decrease of 400 mbar in 12 hours is permissible.
If the vacuum decrease is greater, check for leaks in the vicinity of ...
Brake servoorNon-return valve of vacuum hoses with connectors and vacuum pump/suction pipe..If there are large leaks, the vacuum decreases steeply within a few seconds.
After generation of vacuum, close cut-off valve (A) to check brake servo vacuum system.

Once vacuum has been generated, close shut-off valve (C) to check vacuum system from brake servo vacuum gauge VAS 6721 to intake manifold or to vacuum pump.

Open cut-off valve (B) to facilitate removal of hose connections and adapter.