Checking:
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary coolant heaters -B7W/D7W- › Checking:
Checking:
Special tools and workshop equipment requiredHand multimeter V.A.G 1526B
Not illustrated
- Commercially available measuring glass (0 ml to 25 ml)
Set measuring range selector switch on hand multimeter V.A.G 1526B to DC voltage measurement, measuring range 20 V.
Connect test probes to contacts “T8/6” (positive) and “T6/4” (negative) of heater control unit J162.
Warning Danger of fuel escaping.
Fuel system is under pressure.
Before opening system, wrap a cloth around the connection. Then release pressure by carefully loosening the connection.
Disconnect fuel line at heater unit and insert it in the measuring glass.
Switch water heater on.
Switch heater off as soon as fuel flows into the measuring glass from the fuel line and wait for run-on period to end.
Empty measuring glass and place fuel line in measuring glass.
Switch water heater on.
Fuel delivery begins approx. 55 seconds after switching on.
Read off voltage value on hand multimeter V.A.G 1526B.
Fuel supply is switched off automatically after 90 seconds.
Switch water heater off and compare fuel delivered in measuring glass with values in relevant diagram.
Fuel delivery is OK when the measured values lie within the hatched area of the diagram.
Diagram for D7W (diesel) → Chapter
Diagram for B7W (petrol) → Chapter
Note
- If the ambient temperature is above 20°C, fuel vaporisation may lead to incorrect measurements.
- No bubbles are to be delivered.
Parts & tools for this job For 1990 Volkswagen Transporter
- FLUIDCoolantSearch: Volkswagen coolant antifreeze
- PARTThermostatSearch: Volkswagen Transporter 1990 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester