01 4-cylinder diesel engine (2.0 l engine, common rail)02 4-cylinder diesel engine03 4-cylinder injection engine (2.0 l direct injection engine, turbocharger)04 Fuel supply system - Petrol engines05 Fuel supply system - Diesel engines06 4-cylinder injection engine (2.0 l engine)07 6-cylinder injection engine08 5-cylinder diesel engine09 7-speed dual clutch gearbox 0BT10 6-speed manual gearbox 0A511 5-speed manual gearbox 02Z12 Propshaft and rear final drive13 Automatic gearbox 09K14 Running gear: Guide for using trailers15 Wheels and Tyres Guide - General Information16 Running gear: Guide for increasing and decreasing load ratings17 Wheels and Tyres Guide18 Running gear, axles, steering19 Brake systems20 Heating and air conditioning: Auxiliary heater21 Heating, air conditioning22 Electrical System, General Information23 Electrical: Communication24 Electrical system25 General body repairs, exterior26 General body repairs, interior27 Vehicle-specific paint information28 General body repairs - California
Volkswagen Transporter T5 (2003-2015)07 · 6-cylinder injection engine
07 · Engine

Checking combination valve

Make
Volkswagen
Model
Transporter T5
Year
2003–2015
Section
Secondary air system › Checking combination valve
6-cylinder injection engineChecking combination valve

Checking combination valve

Special tools and workshop equipment requiredHand vacuum pump V.A.G 1390
W00-0515

Test prerequisites

Vacuum pipes and hose connections free of leaks.Vacuum pipes not blocked or kinked.

Test procedure

To achieve sufficient access:

Remove coolant expansion tank from front end. Coolant hoses remain connected.

First pull off connector (1) then pull activated charcoal filter system solenoid valve 1 N80(2) off in (direction of arrow).

N26-10061

Then pull off vacuum hose, leading to combination valve (1), at secondary air inlet valve N112(2).

N26-10059

Connect hand vacuum pump V.A.G 1390 to disconnected vacuum hose (1) leading to combination valve.

N26-10060

Press locking buttons (arrows) together and pull off pressure hose (1).

N26-10062

Note

  • Do not use compressed air during the following check!

Fit test hose onto union and blow into it.

The combination valve must be closed.

Operate hand vacuum pump V.A.G 1390 several times.

Combination valve must open.

If combination valve does not open:

Renew combination valve Item.