Checking combination valve
- Make
- Volkswagen
- Model
- Transporter T5
- Year
- 2003–2015
- Section
- Secondary air system › Checking combination valve
Checking combination valve
Special tools and workshop equipment requiredHand vacuum pump V.A.G 1390
To achieve sufficient access:
Remove coolant expansion tank from front end. Coolant hoses remain connected.
First pull off connector (1) then pull activated charcoal filter system solenoid valve 1 N80(2) off in (direction of arrow).

Then pull off vacuum hose, leading to combination valve (1), at secondary air inlet valve N112(2).

Connect hand vacuum pump V.A.G 1390 to disconnected vacuum hose (1) leading to combination valve.

Press locking buttons (arrows) together and pull off pressure hose (1).

Note
- Do not use compressed air during the following check!
Fit test hose onto union and blow into it.
The combination valve must be closed.
Operate hand vacuum pump V.A.G 1390 several times.
Combination valve must open.
If combination valve does not open:
Renew combination valve Item.
Parts & tools for this job For 2003 Volkswagen Transporter
- PARTEngine gasket setSearch: Volkswagen Transporter 2003 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set