Workshop Manuals Factory service & repair Volkswagen
01 4-cylinder common rail engine (2.0 l, 4V, turbocharger)02 Fuel supply system - petrol engines03 Fuel supply system - Diesel engines04 4-cylinder injection engine (2.0 l direct injection engine, turbocharger)05 4-cylinder diesel engine (2.0 l engine, common rail, generation II)06 5-speed manual gearbox 02Z07 6-speed manual gearbox 0A508 7-speed dual clutch gearbox 0BT09 Propshaft and rear final drive10 Running gear: Guide for using trailers11 Wheels and Tyres Guide - General Information12 Wheels and Tyres Guide13 Brake systems14 Running gear, axles, steering15 Heating, air conditioning16 Heating and air conditioning: Auxiliary heater17 Electrical System, General Information18 Electrical system19 Electrical: Communication20 General body repairs - California21 General body repairs, interior22 General body repairs, exterior
Volkswagen Transporter T6 (2015-2019)18 · Electrical system
18 · Electrical

Preparatory measures for calibration

Make
Volkswagen
Model
Transporter T6
Year
2015–2019
Section
Lane change assist › Preparatory measures for calibration
Electrical systemPreparatory measures for calibration

Preparatory measures for calibration

The lane change assist control unit J769 left (master) and lane change assist control unit 2 J770 right (slave) is joined to the relevant radar sensor to form one unit for each side respectively. They are located behind the end pieces beneath the tail lights and must be calibrated following:

  • Removal and installation of one or both lane change assist control units
  • Any change in the installation position of a lane change assist control unit
  • After removal or installation of one of the covers above the lane change assist control unit

Extensive preliminary work is required before actual calibration can be carried out using vehicle diagnostic tester.

Prerequisites:

Position vehicle on a firm and level surface.Apply parking brake. Vehicle must not be moved during measurement.Align front wheels to straight-ahead position - steering wheel in straight-ahead position.If necessary, remove sticker with metal foil from bumper cover.Nobody must be inside vehicle during measurement.Opening and closing the vehicle doors during calibration must be avoided.

Note

  • If a fault message appears in the display operating instructions of vehicle diagnostic tester.

Special tools and workshop equipment requiredCalibration unit VAS 6350
W00-10488
Vehicle diagnostic tester

Connecting vehicle diagnostic testerChapter

Switch on ignition.

Attach 3 wheel bolt adapters (19 mm) to each wheel centre mounting VAS 6350/1 for the wheel securing bolts.

N94-10685

Insert the measuring paddles in the two wheel centre mountings VAS 6350/1 and secure them with the clamping nut.

Fit the wheel centre mountings VAS 6350/1 onto the wheel bolts on both rear wheels.

Note

  • The turning centre of the wheel centre mounting must be in the turning centre of the wheel.
  • Place wheel centre mountings VAS 6350/1 on wheels so that “anti-theft wheel bolts” are not connected to the wheel centre mountings.

Set measuring paddles with the help of the clamping nuts in such a way that they can move freely just above the floor.

The measuring paddles must not be restricted in movement.The measuring paddles must be vertical.

Position the calibration unit VAS 6350 at a distance of (a) to the rear wheels.

A96-10286
Dimension (a ) = 1700 ± 2 mm

Switch on spacing laser VAS 6350/2 using ON button.

N94-10681

Indicated on display of VAS 6350/2:

“- - - m”

Note

  • The laser is switched on at the same time.

Hold spacing laser VAS 6350/2(2) for distance measurement flush with stop bracket as shown in illustration.

N94-10684

The spacing laser VAS 6350/2 must be firmly in contact with the stop bracket when doing this.

Ensure that the “laser beam” for distance measurement is at the bottom enlarged part on the measuring paddle (1).

If this is not the case, the height of the measuring paddles has to be corrected with the aid of the clamping nuts on the wheel centre mounting VAS 6350/1.

Now, briefly press ON button to measure distance.

A96-10289

Indicated on display of VAS 6350/2:

“1.700 m” (specification: 1700 ± 2 mm).

Repeat the measuring process from the left stop bracket to the measuring paddle on the rear left wheel.

Measured distance value must be identical on both sides.

If both measured values are not identical, adjust calibration unit VAS 6350 accordingly.

Attach the calibration unit for lane change assist VAS 6350/4 on the rear left on the mounting of the calibration unit VAS 6350.

N94-11755

Note

  • If assembled correctly, the mains power lead should be fitted to the bottom left of the calibration unit as seen facing direction of normal travel.

Dimension (a) = 840 mm measured from upper edge of calibration unit to workshop floor.

The dimension is set with the measuring point (arrow) at the base of the calibration unit on the scale of the steel rule (1).

Setting dimension on left read off on measuring scale (1) = 697 mm.

Connect the calibration unit for lane change assist VAS 6350/4 to mains voltage.

Align calibration unit VAS 6350 to horizontal position with the aid of the vial (sight glass) (arrow) by turning the plastic feet.

N94-10686

Put on “laser protection glasses”.

N94-11756

Switch on linear laser VAS 6350/3 on calibration unit VAS 6350.

Align the whole calibration unit VAS 6350 so that the laser beam is focused on the rear of the vehicle in the centre above the VW badge.

Check the spacing on the left and right again between the stop brackets of the calibration unit VAS 6350 and the measuring paddles (1) on the wheel mountings.

N94-10684
Specification: 1700 ± 2 mm

Calibrating lane change assist control unit → Chapter.

Parts & tools for this job For 2015 Volkswagen Transporter