01 4-cylinder common rail engine (2.0 l, 4V, turbocharger)02 Fuel supply system - petrol engines03 Fuel supply system - Diesel engines04 4-cylinder injection engine (2.0 l direct injection engine, turbocharger)05 4-cylinder diesel engine (2.0 l engine, common rail, generation II)06 5-speed manual gearbox 02Z07 6-speed manual gearbox 0A508 7-speed dual clutch gearbox 0BT09 Propshaft and rear final drive10 Running gear: Guide for using trailers11 Wheels and Tyres Guide - General Information12 Wheels and Tyres Guide13 Brake systems14 Running gear, axles, steering15 Heating, air conditioning16 Heating and air conditioning: Auxiliary heater17 Electrical System, General Information18 Electrical system19 Electrical: Communication20 General body repairs - California21 General body repairs, interior22 General body repairs, exterior
Volkswagen Transporter T6 (2015-2019)18 · Electrical system
18 · Electrical

General description - start/stop system

Make
Volkswagen
Model
Transporter T6
Year
2015–2019
Section
Start/stop system › General description - start/stop system
Electrical systemGeneral description - start/stop system

General description - start/stop system

The start/stop system is used for reducing fuel consumption by automatically switching off the engine when the vehicle is stationary and automatically starting it when the driver wants the vehicle to move on. The start/stop mode is automatically activated when, after moving on, the vehicle is driven for about 4 seconds at a minimum speed of 3 km/h.

Battery recharging or jump start on vehicles with start/stop system:

When recharging or jump starting vehicles with start/stop system, note the following: first connect charging cable to battery positive terminal, then body earth. This ensures that the battery monitor control unit J367 is not bridged. Charging the battery directly on the negative terminal causes the battery monitoring control unit to be bridged. The battery data is not collected by the battery monitoring control unit during the charging process. Then, the values concerning the battery state and saved in the data bus diagnostic interface would not correspond to the values of the charged battery.

Renewing battery on vehicles with start/stop system

Note

  • Because of their higher deep-cycle resistance, only special batteries are used in vehicles equipped with a start/stop system.
  • When renewing the battery, note the correct part designation ETKA.
  • Batteries intended for use in vehicles with a start/stop system are marked “AGM” (Absorbent Glass Mat) or “EFB” (Enhanced Flooded Battery).

Fault detection and fault display:

The start/stop system as a function is integrated in the engine control unit J623 software.

The engine control unit J623 features self-diagnosis to facilitate fault finding.

For fault finding, use the systems described in chapter “Vehicle diagnosis, testing and information system” in “Guided Fault Finding” mode → Chapter.