Workshop Manuals Factory service & repair Volkswagen
01 4-cylinder common rail engine (2.0 l, 4V, turbocharger)02 Fuel supply system - petrol engines03 Fuel supply system - Diesel engines04 4-cylinder injection engine (2.0 l direct injection engine, turbocharger)05 4-cylinder diesel engine (2.0 l engine, common rail, generation II)06 5-speed manual gearbox 02Z07 6-speed manual gearbox 0A508 7-speed dual clutch gearbox 0BT09 Propshaft and rear final drive10 Running gear: Guide for using trailers11 Wheels and Tyres Guide - General Information12 Wheels and Tyres Guide13 Brake systems14 Running gear, axles, steering15 Heating, air conditioning16 Heating and air conditioning: Auxiliary heater17 Electrical System, General Information18 Electrical system19 Electrical: Communication20 General body repairs - California21 General body repairs, interior22 General body repairs, exterior
Volkswagen Transporter T6 (2015-2019)17 · Electrical System, General Information
17 · Electrical

Current draw test

Make
Volkswagen
Model
Transporter T6
Year
2015–2019
Section
Checking battery › Current draw test
Electrical System, General InformationCurrent draw test

Current draw test

Warning It is not permissible to test or charge batteries whose magic eye shows light yellow. Do not slave/jump start the vehicle!
Danger of explosion when checking and charging or slave/jump starting.
These batteries must be renewed.

Note

  • Make sure to set the correct charging mode on the charger so that the current draw test is not falsified.
  • Battery charger VAS 5095 A, Chapter
  • Battery charger VAS 5900, Chapter
  • Battery charger VAS 5903, Chapter
  • Battery charger VAS 5906, Chapter
  • Battery charger VAS 5908, Chapter

To quickly ascertain the state of discharged batteries, the battery current draw test whilst charging helps to determine whether the battery must be replaced or fully recharged.

Note

  • For battery tester with printer VAS 6161, the current draw test must always be performed when the test result “Perform current draw test” appears on the display.

Performing a current draw test whilst charging a battery will quickly establish whether a partly or fully discharged battery → Chapter can be recharged to return it to a serviceable condition.

Test requirements:

  • When charging battery, battery temperature must be at least ≥ +10 ℃.
  • The charger must be capable of outputting a charge current of at least 30 A, as for example with VAS 5095A, VAS 5900, VAS 5903
  • The battery's current draw must be measured with a current pick-up clamp, e.g. VAS 5051B/7, when charging with battery charger VAS 5095A. Battery charger VAS 5900 and battery charger VAS 5903 display the current draw on the unit. Battery charger VAS 5900 performs the current draw test automatically with menu guidance.

Connect battery to battery charger and start charging procedure.

Measure charge current of battery after 5 minutes.

Test result:

If the current draw A is higher than 10 % of the nominal capacity (e.g. > 6.1 A for a 61 Ah battery), fully charge battery and test again.

Battery is fully charged if charge current is more than 10 % of rated capacity.

After 2 hours of battery resting time, perform a battery test → Chapter.

Renew battery if the charge current, in amperes, lies below 10% of the rated capacity 5 minutes after the start of charging (i. e. for a 50 Ah battery < 5A). In the event of warranty and goodwill gestures, fill out the battery test sheet.

Parts & tools for this job For 2015 Volkswagen Transporter

As an Amazon Associate we earn from qualifying purchases.