Workshop Manuals Factory service & repair Volkswagen
01 3 - Cyl. injection engine02 3 - Cyl. injection engine (1.0l, turbocharger)03 Troubleshooting, Mechanical Transmission04 5 - Speed manual gearbox 0DF05 5 - Speed automated transmission 0CT06 Brake systems07 Running gear, axles, steering08 Wheels and Tyres - Specifications09 Heating, air conditioning10 Electrical system11 Electrical: Communication12 General body repairs, interior13 General body repairs, exterior
Volkswagen Brazil-market up! (2014-2021)01 · 3 - Cyl. injection engine
01 · Engine

Injection valves - check

Make
Volkswagen
Model
Up! Brazil-market up!
Year
2014–2021
Section
Injection valves › Injection valves - check
3 - Cyl. injection engineInjection valves - check

Injection valves - check

Electrical equipment

Warning Follow the instructions below to prevent severe injuries:

  • With the ignition switched off, disconnect the earth wire from the Battery AElectrical equipmentRep. gr. 27 Starter, alternator, battery
  • Always disconnect the fuel rail supply on the engine compartment connection next to the A-pillar, rather than on the fuel rail.
  • In vehicles equipped with the E-Flex cold start system, the fuel rail may be hot.

W15-0221
Special tools and workshop equipment requiredTorque meter - 5 to 50 Nm ( enc. 1/2") VAG 1331Remote control VAG 1348/3AAdaptor cable V.A.G 1348/3-2 or VAG 1348 adaptor VAG 1348/3-3Auxiliary measurement cable set VAG 1594C or Auxiliary measurement cable set VAG 1594AFlow meter VAG 1602

Injection valves - check resistance

Checking process

Check the injection valve resistance between the contacts (CSEA and CWRA engines). Theoretical value: 11.4...12.6 Ω.

A96-0134

Note

  • The resistance value is valid at a room temperature of approximately 20°C. For higher temperatures, the resistance value increases.

If the theoretical value is not reached:

Replace the faulty injector valve.

The installation of the injector valves should be carried in reverse order of removal, whilst observing the following:

  • The locking rings from all injection valves must be replaced and lubricated with a little clean engine oil.
  • Install injector valves in their correct position on the fuel distributor and immobilize them with fastening clips.
  • Place the fuel rail with the injector valves locked and install it uniformly on the intake manifold.

Flow and jet form of injection valves - check

Verification condition

Fuel pressure OK Chapter.

Test sequence

Remove the air filter line (1).

Remove the air filter fastening bolt.

Move the air filter upwards (2) and slide the filter towards the front of the vehicle, in points (3).

R24-10068

Press the air filter with nozzle in the direction of the (arrow), removing it from the support (4).

Remove the air filter from the engine compartment.

Warning The Chapter“Safety measures regarding work on the fuel supply systems” must be followed.
The fuel supply hose is under pressure! Always wear protection gloves and glasses, so as to prevent serious injuries and contact with the skin. Before loosening hose connections, wrap the connection points with a cloth. Eliminate the pressure, carefully pulling the connection.

Remove fuel rail along with all injection valves → Chapter.

Note

  • Leave the inserted fuel rail loose in the intake manifold in order to prevent impurities from entering the manifold while connecting check devices.

The fuel supply system lines remain connected.Injection valves are not removed from the fuel rail.All injection valve connectors must be removed.

Connect any contact of the injection valve to be checked with the ancillary cable Adaptor cable VAG 1348/3-2 to the Remote control V.A.G 1348/3A.

Connect another contact of the injection valve to be checked with the Auxiliary measurement cable set VAG 1594A or Auxiliary measurement cable set V.A.G 1594C to the engine earth wire.

Connect to the earth wire with the Adaptor cable V.A.G 1594/2, Adaptor cable V.A.G 1594/19 and a Claw VAG 1594/14.

N24-1529

Connect the borne to the Battery A(+) in the engine compartment.

To perform a comparative volume measurement, remove three graduated cups from the Flow meter VAG 1602.

Respectively use a graduated glass for each injection valve to be checked.

Switch on the Vehicle diagnostic tester as indicated below.

N01-0590

Connect the diagnostics cable connector (2) to the respective connection on the driver footwell.

Note

  • During the Fuel pump (pre-supply pump) G6 relay actuator diagnostics process, it is activated only for 30 seconds.
  • As soon as the actuator diagnostics procedure begins, simultaneously press the Remote control V.A.G 1348/3A button.
  • The Remote control V.A.G 1348/3A must be activated until no more injection valve fuel drips.

Turn on the ignition.

Press the following buttons on the display.

  • Self-diagnosis
  • 01 – Electronic engine system
  • 005 - Actuator diagnostics
  • Fuel pump relay
  • Start

Note

  • The ignition must be switched off and on between each injection valve test procedure.
  • If the ignition is not switched off and on, the actuator diagnostics may not be repeated under certain circumstances.

Repeat the verification in the remaining injection valves.

After all injection valves have been tested, put the graduated glasses on a flat surface and compare the injection flow.

CSEA Engine

Nominal value 110.58 to 117.42 ml per valve.

CWRA engine

Nominal value 85.0 to 91.0 ml per valve.

If the measured values of one or more injection valves are below the nominal value:

Replace the defective injection valve → Chapter.

Air-tightness - check:

Verification condition

Fuel pressure OK .Fuel and engine temperature approx. 20 ℃.Fuel rail removed.All injection vale connectors removed.

Warning The Chapter“Safety measures regarding work on the fuel supply systems” must be followed.
The fuel supply hose is under pressure! Always wear protection gloves and glasses, so as to prevent serious injuries and contact with the skin. Before loosening hose connections, wrap the connection points with a cloth. Eliminate the pressure, carefully pulling the connection.

As a safety measure, place a Measurement Becker VAG 1602/1 under all injection valves.

Note

  • Fuel system pressure is generated during the air-tightness test.
  • Valves are not activated.
  • Valves will be damaged if fuel leaks from them.

Switch on the Vehicle diagnostic tester as indicated below.

N01-0590

Connect the diagnostics cable connector (2) to the respective connection on the driver footwell.

Turn on the ignition.

Press the following buttons on the display.

  • Self-diagnosis
  • 01 – Electronic engine system
  • 005 - Actuator diagnostics
  • Fuel pump relay
  • Start

Turn ignition off.

Nominal value: no more than 2 drips may leak during the actuator diagnostics procedure.

If fuel loss is greater:

Replace the defective injection valve → Chapter.

Injection valve installation is performed in reverse sequence to the removal. Follow the instructions below:

The locking rings on all injection valves must be replaced and quickly lubricated with clean engine oil.

Tightening torque:

  • Install the fuel rail with locked injection valves in the intake manifold and fasten it uniformly → Chapter.

Warning When installing the air filter fastening bolt in the intake manifold, screw it in manually to prevent damages to the intake manifold thread. Apply the specified torque immediately after such process Item.

Parts & tools for this job For 2014 Volkswagen Up!