| Repairs to CAN bus wiring can be carried out either with sections of repair wiring with the correct cross section or with entwined wires „green/yellow“ or „white/yellow“ from the electronic parts catalogue (ETKA) → Electronic parts catalogue (ETKA). |
t
| When repairs are performed, both bus wires must have the same length. When twisting the wires -1- and -2- together, the length of each complete twist must be A = 20 mm. |
t
| There must not be any section of wiring, for example in the vicinity of crimp connectors -arrow-, longer than B = 50 mm with the wires not twisted. |
t
| Mark the area of repair with yellow insulation tape to make it easy to identify. |
|
|
|