Adapting and filling refrigerant oil
- Make
- Volkswagen
- Model
- XL1 plug-in hybrid
- Year
- 2014–2016
- Section
- Repair notes › Adapting and filling refrigerant oil
Adapting and filling refrigerant oil
Special tools and workshop equipment requiredE.g. air conditioner service station VAS 6007A (or later model)



Observe instructions when working on refrigerant circuit → Chapter.
Warning Danger from escaping pressurised refrigerant!
Freezing of skin and other body parts.
Extract refrigerant and then immediately open refrigerant circuit.If the refrigerant was extracted more than 10 minutes before the opening of refrigerant circuit, the refrigerant must be extracted again. The pressure in the circuit will increase due to subsequent evaporation.
Note
- Releasing refrigerant into the environment is a criminal offence.
- All components of the refrigerant circuit which have been opened must be sealed with suitable plugs to prevent moisture intrusion.
Extract refrigerant with e.g. air conditioner service station VAS 6007A.
Unscrew protective cap (1).

Unscrew valve (2) with socket T10364.
Fill as much new refrigerant oil as has been extracted into the low-pressure line with a commercially available disposable syringe.
Installation is carried out in the reverse order. When installing, note the following:
Evacuate and fill air conditioning system only via the high-pressure line.
| Component | Specified torque |
|---|---|
| Protective cap | 0.4 Nm |
| Valve | 2 Nm |