240 L6-2383cc 2.4L DSL SOHC D24 FI (1982)
![background image](/volvo/240/l6-2383cc_2.4l_dsl_sohc_d24_fi/Page-449054.png)
The armature should not grind against pole shoes and field coils. Diameter of end of coil must not be more than that of armature coil. Max. radial throw
= 0.05 mm (0.002 in). Test armature for arcing and open circuits with appropriate test equipment.
M8 Arcing
Test commutator for arcing to ground.