740 L4-2320cc 2.3L DOHC B234F (Can) (1992)
-
Clamp cables using strip clamps for existing cables
D5
Location of opening in cable sheath
The cable sheath is cut to drain of condensation.
-
The cut conduit section should be placed at the lowest point in the cable routing.
-
Use butyl tape to seal the grommet.
-
Use existing clamps to clamp up the cables to firewall.
D6
Connection of yellow connector
-
Disconnect the yellow connector from the heater and attach the yellow connector from the cable harness.
-
Install the detached connector in the cable harness other yellow connector.
D7
Connection of orange cable
-
Route the orange cable with connector to driver's side of center console.
-
Locate the black 4-pin accessories connector
The connector can be connected to accessories (A) or unused (B).
-
(A) If accessories are connected. separate connectors and connect them to both connectors on the new cable harness.