volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Multiport Fuel Injection (MFI) System LH 2.4|Page 2849 > < Multiport Fuel Injection (MFI) System LH 2.4|Page 2847
Page 3
background image

Throttle position (TP) switch 

Sends signals to the MFI and DI system control modules that the throttle is closed or wide open.

In the B204FT/GT the TP switch also contains a potentiometer which sends the TC control system information about the throttle position.

TC models do not use the full load switch.

Heated oxygen sensor (HO2S) 

Normally 14.7 kg air to 1 kg fuel is given as the ideal mixture for complete combustion. This mixture is called lambda = 1. The mixture can be
gauged by measuring the oxygen content of the exhaust gases after combustion by using an HO2S.

The HO2S produces a voltage signal proportional to the oxygen content in the exhaust gases. This signal alternates from high to low at the ideal
mixture of 14.7 kg air/1 kg fuel. A rich mixture produces a high voltage while a weak mixture produces a low voltage. This voltage varies between
0.1-0.9 volt. The control module bases the quantity of fuel injected on this signal so as to achieve the ideal mixture, lambda = 1.

The HO2S will only operate above a certain temperature, approx. 285°C (545°F). It is electrically heated so that it reaches operating temperature
quickly. When the ignition is switched on a current is applied to a PTC resistor, the resistance of which increases with temperature. This provides a
short warm up time and keeps the sensor at the correct operating temperature when the exhaust gas temperature is low.

In engines without a TWC (B 230 GT, B 204 GT), i.e engines for markets where unleaded gasoline is not fully available, an HO2S which can
withstand leaded fuel must be used. However, this HO2S has a limited lifespan and must be replaced regularly.

Multiport Fuel Injection (MFI) System LH 2.4|Page 2849 > < Multiport Fuel Injection (MFI) System LH 2.4|Page 2847