CO% Adjustment Using Test Diode|Page 1113 > < CO% Adjustment Using Test Diode
Page 2
background image

If idle speed is incorrect, see IDLE SPEED for more adjustment procedures.

Fig. 399 CHECK TIMING

11.

Check ignition setting at idle speed.

Reading should be:

16° ±2 

Timing can only be checked, no adjustments are possible.

Fig. 342 CHECK AND ADJUST CO

12.

Check CO content. Test diode should blink if CO content is correct.

13.

If test diode remains on, the CO content is to high.

14.

If test diode remains off, the CO content is to low. 

Fig. 370 REMOVE CO ADJUSTMENT SEAL

15.

To adjust CO, turn off engine.

16.

Drill two 2 mm (0.08 in.) holes into the plug.

CO% Adjustment Using Test Diode|Page 1113 > < CO% Adjustment Using Test Diode