780 V6-2849cc 2.8L SOHC B280F (1987)
Compressor Clutch Relay: Testing and Inspection
Compressor Delay Relay
Compressor delay relay - check for supply at terminal 87 after connection.
1. Connect 12 V supply to terminals 61 and 15.
2. Ground terminal 85.
3. Check for supply at terminal 87 after 10 seconds:
-
no supply, faulty relay
-
supply, relay OK.