850 T-5 L5-2.3L Turbo VIN 58 B5234T5 (1997)
Hydraulic Modulator Assembly: Electrical Specifications
With Traction Control
SPECIFICATIONS
Power supply ......................................................................................................................................................................................................... 10-16 V
Type ................................................................................................................................................................................................ Eccentric piston pump
Working pressure ...................................................................................................................................................................... 0.1-20 MPa (15-3000 psi)
Overflow valve, opening pressure .................................................................................................................... 6.5 +/- 4.0/0.8 MPa (950 +/- 600/200 psi)
Rotation Sensor
Resistance .................................................................................................................................................................................................. 10-40 ohms
Output voltage, minimum 350 mV AC at frequencies greater than 130 Hz
Electromagnetic Hydraulic Valves
Resistance, inlet valve, TRACS valve .......................................................................................................................................................... 6-8 ohms
Resistance, outlet valve ................................................................................................................................................................................. 3-5 ohms
Without Traction Control
SPECIFICATIONS
Power supply ......................................................................................................................................................................................................... 10-16 V
Type ................................................................................................................................................................................................ Eccentric piston pump
Working pressure ...................................................................................................................................................................... 0.1-20 MPa (15-3000 psi)
Rotation Sensor
Resistance .................................................................................................................................................................................................. 10-40 ohms
Output voltage, minimum 350 mV AC at frequencies greater than 130 Hz
Electromagnetic Hydraulic Valves
Resistance, outlet valve ................................................................................................................................................................................. 3-5 ohms