7. Remove fluid pipe. (Q7)
-
Disconnect pipe connection to condenser.
-
Disconnect snap-on couplings from center board, using removal tool 5385.
8. Mark position of pipes relative to one another.
-
Separate flange connection and replace/clean out expansion pipe.
-
Expansion pipe can be removed using pointed pliers.
-
Replace pipes if necessary.
Installation:
NOTE: Use new 0-rings lubricated with compressor oil in all pipes and snap-on connections.
-
Expansion pipe, torque setting 30 Nm (22 ft.lb.).
NOTE: Observe marking when tightening flange.
-
Fluid pipe, connection to compressor: torque setting 20 Nm (15 ft.lb.).
-
Refrigerant pipe between evaporator and receiver/dryer, remove plug to dryer bottle first.
-
Pressostat connector.
-
Expansion chamber connector.
-
Control unit box air intake hoses.
-
Battery negative cable.
-
Fill system with refrigerant and test for leaks. See: Service and Repair