940 L4-2.3L SOHC VIN 88 B230F (1992)
Remove grey/black (GR-SB) lead from position 32 in connector.
Cut lead 1.75" from connector entry as illustrated.
Remove green-yellow (GN-Y) lead from position 15 in connector.
Cut lead 3.25" from connector entry as illustrated.
Remove green-red (GN-R) lead from position 14 in connector and insert in position 15
Caution!
Remove lead carefully to avoid damage to terminal.
To insulate ends of the gray/black and green/yellow leads, crimp splicing sleeves, P/N 956958-3, onto uncut ends.
Note:
Do not strip ends and ensure that sleeves are securely crimped in position. Replace protective cover over connector. Bend rubber protector back into