 The abbreviation VVT stands for: 
 Variable 
 Valve 
 Timing. 

Note! Crankshaft or camshafts must  not, under any circumstances, be rotated more than is listed below. Failure to follow these instructions
may cause damage to the valves.
 

Remove: 

-

the cable from the battery negative terminal.  Battery, disconnecting See: Starting and Charging/Battery/Service and Repair/Procedures/Battery,
Disconnecting.

-

the charge air pipe over the engine.

Seal the openings.

-

the upper camshaft belt cover.

-

the cover over the ignition coils.

-

lift the solenoid valves away from the air cleaner (ACL) cover.

-

the air intake hose for the turbocharger (TC) from the air cleaner (ACL) cover.

Put to one side.

-

the upper torque rod bracket.

-

the camshaft position (CMP) sensor housing.

-

the trigger wheel.

-

the rear cover for the intake camshaft.

-

the servo reservoir and the expansion tank.

Lift up and place on top of the engine.

Note! Take care not to spill servo oil from the bleed hole in the cap. Place paper wipe around the reservoir and then cover with a plastic
bag as protection. Spilled servo oil is highly inflammable.
 

-

3 nuts for the cable duct at the right suspension turret.

Lift the duct away from the screws.

-

the auxiliaries belt.

-

the front camshaft belt cover.

Position the engine according to the marking 