To access relay 212 (2/5), see Replacing relay in passenger compartment central electrical unit. 

After performing this procedure, See: Verification

Checking the Wiring - III

Checking The Wiring 

-

Disconnect the control unit connector.

If the seat-belt reminder comes on/ticks weakly the whole time, a short circuit to voltage supply has probably damaged the control unit. The short circuit
must be remedied before any component is replaced.

Check whether there is a short circuit to voltage supply by: 
Ignition on.

Measure the current between #34 and ground. The current should not be greater than 60 mA.

Check #34 for a short circuit to ground, as described in Checking wiring and terminals - Permanent faults.

Check #34 for a short circuit to voltage supply, as described in Checking wiring and terminals - Permanent faults.

Check also relay 212 (2/5) #6 for a short circuit to ground, as described in Checking wiring and terminals - Permanent faults.

If no fault is found, test by using a new seat-belt reminder.

See: Restraint Systems/Air Bag Systems/Testing and Inspection/Component Tests and General Diagnostics/Component Tests and General
Diagnostics/Checking Wiring and Terminals - Permanent Faults 

Do the necessary corrective action.

Additional information 

-

To access/replace control unit, see SRS control module 

-

To access/replace the seat-belt reminder, see Replacing relay in passenger compartment central electrical unit. 

After performing this procedure, See: Verification 

Verification

Verification 

-

Install components etc.

Hint: After the repair it is necessary to check that the fault has disappeared.

Check the seat-belt reminder function.

Test Complete