Read  Before starting work on the refrigerant circuit.

-

Drain the system of refrigerant, according to  Refrigerant, overview See: Heating and Air Conditioning/Description and Operation/Refrigerant,
Overview  and  Emptying/vacuum pumping/filling with refrigerant See: Heating and Air Conditioning/Service and Repair/Emptying/Vacuum
Pumping/Filling With Refrigerant.

-

Mark the position of the pipes in relation to each other at the flanged joint.

-

Disconnect at the flanged joint.

-

Remove expansion valve.

Installing expansion valve 
In reverse order.
Tighten to 30 Nm.

Installing refrigerant pipe/hose; member - evaporator  

In reverse order.