S40 L4-1.9L Turbo VIN 29 B4204T3 (2001)
Reason
Incorrect crimping as shown above can be caused by:
-
Cable terminal is the wrong size for the cable area
-
The wrong crimp tool or the wrong forming section in the crimp tool was used.
Incorrect location of cable/cable terminal
The stripped cable is not located correctly
The cable has not been pushed far enough in.
The entire stripped core must be located within the core crimp.
The stripped core is too short
The cable insulation is too far forward and has caught under the core crimp.
The stripped core is too long
The insulation is not fully located in the insulation wings.
The stripped core is too long
The stripped core is too far forward past the core crimp.
The stripped core is incorrectly crimped
The strip section is the right length but one of the copper strands is outside the terminal, indicating the terminal was incorrectly located in the crimp tool
forming jaws.
All of the strands must be pressed together within the core wings.