Blower Motor: Testing and Inspection
Checking The Blower Fan Control

Trouble-Shooting Information

Condition

-

No diagnostic trouble codes are stored

-

Fault is permanent.

Possible source

-

Motor signal wire has open circuit or short circuit to ground

-

Control signal wire has open circuit or short circuit to voltage supply/ground

-

Diagnostic signal wire has open circuit or short circuit to voltage supply/ground

-

Motor ground wire has open circuit or short circuit to voltage supply

-

Defective fan motor or power unit

-

Fan motor blocked

-

Contact resistance, oxidation or loose contact in connector.