S60 L5-2.4L VIN 64 B5244S6 (2003)
Measurement range: 0 - 100%
The climate control module (CCM) calculates the value based on the stage movement of the damper motor.
Air distribution damper motor position, value (Manual climate control / standard)
Measurement range: 0 - 100%
The climate control module (CCM) calculates the value based on the stage movement of the damper motor.
Air distribution selector, defroster position, status (Manual climate control / standard)
The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.
Off = Inactive
On = Active
Air distribution selector, ventilation position, status (Manual climate control / standard)
The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.
Off = Inactive
On = Active
Air distribution selector, floor position, status (Manual climate control / standard)
The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.
Off = Inactive
On = Active
Air distribution selector, floor / defroster position, status (Manual climate control / standard)
The status displays whether the signal from the air distribution selector for the climate control module (CCM) is active or not.
Off = Inactive
On = Active
Temperature damper motor, left activation, value
Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.
Temperature damper motor, right activation, value
Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.
Recirculation damper motor activation, value
Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.
Floor / ventilation damper motor activation, value (Electronic climate control)
Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.
Defroster damper motor activation, value (Electronic climate control)
Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.
Air distribution damper motor activation, value (Manual climate control / standard)
Measurement range: 0 - U(bat)
The climate control module (CCM) transmits a signal to the damper motor for stage movement.
Air quality sensor, value (Electronic climate control)
Measurement range 0 -100%