Refrigerant: Service and Repair
Refrigerant, Draining

Refrigerant, draining

Draining refrigerant

Information

Note! The ambient temperature must be above 20°C when draining the system

When draining refrigerant, the recycling unit can be attached to the service valve for both the high pressure side (HP) and the low pressure side (LP) at
the same time. This is the quickest method.

-

The engine must be switched off

-

Check the amount of oil (if any) that has run out when draining the refrigerant.

Note! The recycling unit must be equipped with an oil separator. The oil separator must be of a type that allows the amount of oil in the 
refrigerant to be measured.

Note! Always disconnect the battery lead when working on the climate control system. Disconnect the battery lead. See Battery, replacing See:
Starting and Charging/Battery/Service and Repair/Removal and Replacement/Battery, Replacing.

Other information:

-

For vacuum pumping, see Vacuum pumping See: Heating and Air Conditioning/Service and Repair/Vacuum Pumping 

-

For visual and physical checks, see Visual and physical check See: Powertrain Management/Computers and Control Systems/Testing and
Inspection/Initial Inspection and Diagnostic Overview/Visual and Physical Check 

-

To fill with refrigerant, see Filling with refrigerant See: Heating and Air Conditioning/Service and Repair/Filling With Refrigerant 

-

To fill with fluorescent tracing agent, see the relevant procedure.

-

To leak trace using an electronic leak tracer, see Leak tracing, electronic leak tracer See: Heating and Air Conditioning/Testing and
Inspection/Component Tests and General Diagnostics/Leak Tracing, Electronic Leak Tracer 

-

To leak trace using fluorescent tracing agent and an UV flashlight, see Leak tracing, fluorescent tracing agent / UV lamp  See: Heating and Air
Conditioning/Testing and Inspection/Component Tests and General Diagnostics/Leak Tracing, Fluorescent Tracing Agent / UV Lamp 