volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

System Overview|Page 273 > < System Overview|Page 271
Page 2
background image

The climate control module (CCM) obtains the value via the control area network (CAN) from the passenger door module (PDM) (left-hand drive) or the
driver door module (DDM) (righthand drive).
The value is used to control the passenger compartment temperature.

Blower fan motor power unit, diagnostic signal, value

The climate control module (CCM) generates an analogue signal.
This is converted to a current which the power unit converts back to an analogue signal. The diagnostic signal is an extremely intense signal that cannot
be used when checking the blower fan.

Guide current for the blower fan motor power unit, value

Measurement range: 0 - 10 mA
The climate control module (CCM) calculates the value based on the signal from the control knob for the blower fan. With electronic climate control, the
value is also affected by automatic climate control (AUTO position).
The value is used to control the power supply from the power unit to the blower fan motor.

Lower switch approval, status

The status displays whether the identity of a certain switch is permissible or missing compared with the permitted switch identities in the Car
Configuration File.
Ok = Switch permitted
Faulty = Switch not permitted

Lower switch, status

Displays the status of a certain switch.
Off = Active signal
On = Signal not active

Lower switch identity, status

The status displays the function of a certain switch. The functions are as follows:
Fold down head restraints
Folding power door mirrors
Private locking (boot lid)
STC
DSTC
Auxiliary lamps
Deadlock (temporary disengagement of the movement and tilt sensors in the alarm)
Reverse warning
Bi-fuel
Child-proof lock
Rear A/C

Temperature damper motor, left position, value

Measurement range: 0 - 100%
The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Temperature damper motor, right position, value

Measurement range: 0 - 100%
The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Recirculation damper motor position, value

Measurement range: 0 - 100%
The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Floor / ventilation damper motor position, value (Electronic climate control)

Measurement range: 0 - 100%
The climate control module (CCM) calculates the value based on the stage movement of the damper motor.

Defroster damper motor position, value (Electronic climate control)

System Overview|Page 273 > < System Overview|Page 271