Workshop Manuals Factory service & repair Volvo
01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Powertrain Management06 Transmission and Drivetrain07 Brakes and Traction Control08 Starting and Charging09 Power and Ground Distribution10 Steering and Suspension11 Heating and Air Conditioning12 Restraint Systems13 Accessories and Optional Equipment14 Body and Frame15 Cruise Control16 Instrument Panel, Gauges and Warning Indicators17 Lighting and Horns18 Windows and Glass19 Wiper and Washer Systems
Volvo S60 L5-2.4L VIN 64 B5244S6 (2003)02 · Sensors and Switches
02 · Diagnostics

Rain Sensor: Diagrams (page 92 of 166)

Make
Volvo
Model
S60
Engine
L5-2.4L VIN 64 B5244S6
Year
2003
Section
Sensors and Switches - Wiper and Washer Systems › Rain Sensor › Diagrams
Sensors and SwitchesDiagram Information and Instructions · page 92 of 166
Rain Sensor: Diagrams (page 92 of 166) – Volvo S60 L5-2.4L VIN 64 B5244S6 (2003)

Always check the control module and control module box connectors to ensure that their pins and sockets are not bent or damaged, as this can cause
faults.

Check pins and terminals particularly for this fault. See "Check Terminals Visually."
 

Short-Circuit to Ground, Permanent Faults

Short-circuit to ground, permanent faults

A short-circuit between a live cable and ground is often indicated by the loss of a function or a fuse blowing when a current is passed through the cable.

Repair wiring and cable terminals, using appropriate procedures. 
 
Checks:

-

Check terminals visually.

-

Activate all switches and sensors in the circuit. Check whether the fuse blows

-

Disconnect the connectors in the circuit to ensure that they do not affect readings.

Use an ohmmeter to take a resistance reading between the cable and ground.
The ohmmeter should read infinite resistance if no components are connected.

Check pins and terminals particularly for this fault. See "Check Terminals Visually."
 

Short-Circuit to Supply Voltage. Permanent Faults

Short-circuit to supply voltage. Permanent faults

A short-circuit between a cable and supply voltage is often indicated by the loss of a function or a fuse blowing when voltage is passed through the cable.

Repair wiring and cable terminals, using appropriate procedures. 
 
Checks:

-

Use a voltmeter to take readings at various points in the circuit while operating switches and sensors.

Voltmeter readings will depend on which circuit is tested and the status of switches and sensors, Use the wiring diagram to determine the correct voltage
in the circuit.
Use an ohmmeter between the suspect cables to detect short-circuits between them.
The ohmmeter should read infinite resistance between cables not connected to each other in the circuit.
Check pins and terminals particularly for this fault. See "Check Terminals Visually." 
 

Inspect Terminals Visually

Pinch or Ctrl + scroll to zoom. Double-tap to reset.

Parts & tools for this job For 2003 Volvo S60 2.4L

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.