S70 L5-2.4L VIN 55 B5254S (1998)
Thread the larger piece of heat-shrink tubing onto the new cable harness.
Cut off the two smaller pieces of heat-shrink tubing to 30 mm long.
Thread them onto the 65 mm long, stripped cables.
Strip cable pairs
Strip insulation on the 4 cable ends 13 mm with pliers 951 2620.
Twist cable ends
There may be a thin plastic film residue on the white (tinned) conductor units.
Untwist the stripped cable ends a little and twist them together again. For safety reasons, do the same with all four stripped cable ends.
Splice the same colored cable ends