Checking Contact Resistance

Checking Contact Resistance

-

Disconnect central locking switch.

-

Check central locking switch and VGLA control module connectors for contact resistance and oxidation, See: Diagnostic Trouble Code Tests and
Associated Procedures/Related Tests and Information/Checking Wiring and Terminals - Permanent Faults 

-

Ignition on.

-

Depress central locking switch to its locking position.

Read off central locking switch status.
The value should be low when the central locking switch is depressed to its locking position
If the value is OK the cause of the fault has been loose connections in the connectors.

Is the value OK?

Yes

-

See: Checking Central Locking Switch, Driver's Door/Verification 

No

-

See: Checking Central Locking Switch, Driver's Door/Checking Cables

Checking Cables

Checking Cables

Check cable between central locking switch connector terminal 5 and ground for an open-circuit See: Diagnostic Trouble Code Tests and Associated
Procedures/Related Tests and Information/Checking Wiring and Terminals - Permanent Faults 
 
Were any faults found in the cable?

Yes

-

See: Checking Central Locking Switch, Driver's Door/Verification 

No

-

See: Checking Central Locking Switch, Driver's Door/Replacing Component 

Replacing Component

Replacing Component

Replace central locking switch.