volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Reading and Clearing Diagnostic Trouble Codes|Page 8419 > < Reading and Clearing Diagnostic Trouble Codes|Page 8417
Page 52
background image

Checking Cables

Check cable between VGLA control module #A6 and central locking switch connector terminal 6 for an open-circuit See: Diagnostic Trouble Code
Tests and Associated Procedures/Related Tests and Information/Checking Wiring and Terminals - Permanent Faults 
 
Was a fault found in the wiring?

Yes

-

See: Checking the Passenger Door Central Locking Switch/Verification 

No

-

See: Checking the Passenger Door Central Locking Switch/Replacing Component 

Replacing Component

Replacing Component

Replace central locking switch.

After performing this procedure See: Checking the Passenger Door Central Locking Switch/Verification

Verification

Hint: After carrying out the repair check that the fault has been remedied as follows:

-

Ignition off.

-

Reconnect connectors, reinstall components

-

Close all doors.

Lock and unlock the driver's and passenger doors using the central locking switches.

Fault Tracing Information

Fault Tracing Information

Condition

-

No diagnostic trouble codes (DTCs) stored.

-

The courtesy lighting can be controlled using the switch in roof lamp.

Possible source

-

Open-circuit in control signal cable to courtesy lighting.

Checking Voltage

Checking Voltage

Reading and Clearing Diagnostic Trouble Codes|Page 8419 > < Reading and Clearing Diagnostic Trouble Codes|Page 8417