S70 GLT L5-2.4L Turbo VIN 56 B5254T (1998)
Hold the cable in the position it is to be fixed and check that the cable is not stretched.
If the cable is stretched, position cable on the other side of the turbocharger control valve (TCV) hoses which are under the MAF sensor.
Install tie strap (A) (P/N 948211-8) as illustrated.
5
Check
-
Check that the clearance between MAF connector and fuse is 3.2 mm (1/8") or more.
-
Check that the fresh air intake is properly secured on the turbo charger (TC). If necessary tighten clamp.